Donate Help Contact The AHA Sign In Home
American Heart Association
Hypertension
Search: search_blue_button Advanced Search
Hypertension. 1995;26:383-389

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Blank, S. G.
Right arrow Articles by Pickering, T. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Blank, S. G.
Right arrow Articles by Pickering, T. G.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*High Blood Pressure

(Hypertension. 1995;26:383-389.)
© 1995 American Heart Association, Inc.


Articles

Isolated Elevation of Diastolic Blood Pressure

Real or Artifactual?

Seymour G. Blank; Samuel J. Mann; Gary D. James; James E. West; Thomas G. Pickering

From the Cardiovascular Center, The New York HospitalCornell University Medical Center, New York, NY (S.G.B., S.J.M., G.D.J., T.G.P.); Department of Electromechanical Engineering Technology, New York City Technical College/CUNY, Brooklyn, NY (S.G.B.); and Acoustic Research Department, AT&T Bell Laboratories, Murray Hill, NJ (J.E.W.).

Correspondence to Seymour G. Blank, PhD, Department of Electromechanical Engineering Technology, New York City Technical College, 186 Jay St, Room V633, Brooklyn, NY 11201.

Abstract Not infrequently, blood pressure measurement by the standard auscultatory technique yields a normal systolic pressure with an elevated diastolic pressure. The relatively narrow pulse pressure of such a measurement raises concern about the accuracy of the blood pressure measurement. The purpose of this study was to assess the accuracy of auscultatory blood pressure measurements in patients with an uncommonly narrow pulse pressure, particularly patients with an elevated diastolic but normal systolic pressure. Auscultatory blood pressure measurements were compared with an objective noninvasive standard, called K2 analysis, which has been shown to be more accurate than the auscultatory technique. Blood pressure was measured simultaneously by auscultatory and K2 techniques in 175 subjects. Comparisons were performed (1) in the group as a whole, (2) in four clinical subgroups (normotensive [<140/<90 mm Hg, n=69], hypertensive [>=140/>=90 mm Hg, n=53], isolated systolic hypertensive [>=140/<90 mm Hg, n=38], and isolated diastolic hypertensive [<140/>=90 mm Hg, n=15]), and (3) in two subgroups whose ratio of pulse pressure to diastolic pressure was greater than or equal to 0.45 (n=151) or less than 0.45 (n=24). Subjects in the isolated diastolic hypertensive group and in the group with a pulse pressure ratio less than 0.45 were considered to have a narrow pulse pressure. In the group as a whole, consistent with previous auscultatory-K2 comparisons, systolic pressure was slightly higher and diastolic pressure slightly lower when measured by K2 versus the auscultatory technique (auscultatory, 145/85 mm Hg; K2, 147/83 mm Hg). For diastolic pressure auscultatory measurements averaged 7 mm Hg greater than K2 in the isolated diastolic hypertensive group (94±4 versus 87±5 mm Hg) but were less than 3 mm Hg (greater) in the other three groups (P<.0004). For systolic pressure, differences were less than 3 mm Hg in all four clinical groups. Auscultatory-K2 differences of diastolic pressure exceeding 5 mm Hg (and 10 mm Hg) were seen in 73.3% (and 40.0%) of isolated diastolic hypertensive subjects versus only 14.5% (2.9%) of normotensive subjects, 22.6% (1.9%) of hypertensive subjects, and 7.9% (2.6%) of isolated systolic hypertensive subjects (P<.0001). Similarly, the auscultated diastolic pressure exceeded the K2 measurement by at least 5 mm Hg (and 10 mm Hg) in 62.5% (29.2%) of subjects with a pulse pressure ratio less than 0.45 versus 13.9% (2.0%) in subjects with a ratio greater than or equal to 0.45 (P<.0001). Auscultatory-K2 differences of diastolic pressure were strongly and inversely related to the pulse pressure ratio (r=-.68, P<.0001) independent of sex, race, or body weight. In conclusion, when the pulse pressure is particularly narrow, auscultation frequently overestimates the true diastolic pressure by 5 mm Hg or more. The treatment implications of this finding, particularly in patients with elevated diastolic but normal systolic pressure, merit further study.


Key Words: pseudohypertension • blood pressure determination




This article has been cited by other articles:


Home page
CirculationHome page
S. S. Franklin, J. R. Pio, N. D. Wong, M. G. Larson, E. P. Leip, R. S. Vasan, and D. Levy
Predictors of New-Onset Diastolic and Systolic Hypertension: The Framingham Heart Study
Circulation, March 8, 2005; 111(9): 1121 - 1127.
[Abstract] [Full Text] [PDF]