(Hypertension. 1997;29:1039-1043.)
© 1997 American Heart Association, Inc.
Articles |
From the Lown Cardiovascular Research Laboratory, Brookline, and Department of Nutrition, Harvard School of Public Health, Boston, Mass.
Correspondence to Dr Paul Grossman, Lown Cardiovascular Research Laboratory, 21 Longwood Ave, Brookline, MA 02146. E-mail pgrossman{at}cybercom.net
Abstract Finapres finger blood pressure monitoring appears to provide a reliable alternative to intra-arterial blood pressure measurement under many circumstances. However, few studies have focused on the limitations of Finapres assessment. In a previous pilot investigation, we observed that Finapres pressure following mental stressors failed to return to initial resting levels. Our objectives in the present study were to (1) replicate earlier findings, (2) examine whether local changes in the measured finger were responsible for the observed drift, and (3) test a method to facilitate the return of pressure to systemic baseline levels. We studied two groups of healthy subjects who underwent a protocol consisting of two mental stressors preceded and followed by baseline periods. In the control group, the Finapres continuously monitored pressure on a single finger for the entire protocol. The intervention group periodically had the Finapres cuff removed and the measured finger exercised to prevent local changes that might influence Finapres estimation of blood pressure. Comparisons indicated a groupxbaseline interaction effect for systolic and diastolic pressures (P<.0004 and P<.003, respectively). The group with the exercise intervention showed much greater recovery during the final baseline than the control group. Recovery of pressures in the control group but not the intervention group was inversely related to the stress level of blood pressure (r=.86, P<.0002), indicating a relationship between blood pressure rise and the degree of distortion of subsequent baseline values. On the basis of our results, we propose that in prolonged protocols, the measurement finger be exercised to facilitate accurate measurements of finger pressure with the Finapres.
Key Words: blood pressure monitoring baroreflex hemodynamics
This article has been cited by other articles:
![]() |
Z. Lu and R. Mukkamala Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis J Appl Physiol, August 1, 2006; 101(2): 598 - 608. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Lipman, P. Grossman, S. E. Bridges, J.W. Hamner, and J. A. Taylor Mental Stress Response, Arterial Stiffness, and Baroreflex Sensitivity in Healthy Aging J. Gerontol. A Biol. Sci. Med. Sci., July 1, 2002; 57(7): B279 - 284. [Abstract] [Full Text] |
||||
![]() |
B. P.M. Imholz, W. Wieling, G. A. van Montfrans, and K. H. Wesseling Fifteen years experience with finger arterial pressure monitoring:: assessment of the technology Cardiovasc Res, June 1, 1998; 38(3): 605 - 616. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. M. Stauss, E. A. Anderson, W. G. Haynes, and K. C. Kregel Frequency response characteristics of sympathetically mediated vasomotor waves in humans Am J Physiol Heart Circ Physiol, April 1, 1998; 274(4): H1277 - H1283. [Abstract] [Full Text] [PDF] |
||||
|
Hypertension Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1997 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |