AbstractThe approach of establishing a time-specified tolerance limit reflecting the circadian variability in blood pressure and then determining the hyperbaric index, the area of blood pressure excess above the upper limit of the tolerance interval, has been proposed for diagnosing hypertension as well as for evaluating the patients response to treatment. The retrospective evaluation of this test provided high sensitivity and specificity in the diagnosis of hypertension, with a threshold value for the hyperbaric index of 15 mm Hg · h. To evaluate the stability and reproducibility of this tolerance-hyperbaric test, we studied 332 previously untreated subjects (218 men) who underwent sequential 48-hour ambulatory blood pressure monitoring for 2 years, providing a total of 1337 blood pressure profiles. Diagnosis of hypertension was established for each subject on the restricted basis of presenting at least 1 blood pressure profile with a hyperbaric index above the previously defined threshold. Sensitivity of this tolerance-hyperbaric test was 98.6%, with a negative predictive value of 99.7%. For the same subjects, the blood pressure load (percentage of values >140/110/90 mm Hg for systolic/mean arterial/diastolic blood pressure during activity or >120/95/80 mm Hg during resting hours) had a sensitivity of 49% and specificity of 25%. The 24-hour mean, still the most common approach for diagnosing hypertension on the basis of ambulatory monitoring, had sensitivities of 40% and 31% for systolic and diastolic blood pressure, respectively. Despite the limitations of ambulatory blood pressure monitoring, the tolerance-hyperbaric test represents a reproducible, noninvasive, and high-sensitivity test for the identification of subjects in need of prophylactic or therapeutic intervention.
Key Words: blood pressure hyperbaric index normotension hypertension
This article has been cited by other articles:
![]() |
R. C. Hermida and D. E. Ayala Sampling Requirements for Ambulatory Blood Pressure Monitoring in the Diagnosis of Hypertension in Pregnancy Hypertension, October 1, 2003; 42(4): 619 - 624. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Hermida, C. Calvo, D. E. Ayala, J. E. Lopez, J. R. Fernandez, A. Mojon, M. J. Dominguez, and M. Covelo Seasonal Variation of Fibrinogen in Dipper and Nondipper Hypertensive Patients Circulation, September 2, 2003; 108(9): 1101 - 1106. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Hermida and D. E. Ayala Prognostic Value of Office and Ambulatory Blood Pressure Measurements in Pregnancy Hypertension, September 1, 2002; 40(3): 298 - 303. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Hermida, C. Calvo, D. E. Ayala, J. R. Fernandez, L. M. Ruilope, and J. E. Lopez Evaluation of the extent and duration of the "ABPM effect" in hypertensive patients J. Am. Coll. Cardiol., August 21, 2002; 40(4): 710 - 717. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Hermida and D. E. Ayala Evaluation of the Blood Pressure Load in the Diagnosis of Hypertension in Pregnancy Hypertension, September 1, 2001; 38(3): 723 - 729. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Hermida, D. E. Ayala, A. Mojon, and J. R. Fernandez Time-Qualified Reference Values for Ambulatory Blood Pressure Monitoring in Pregnancy Hypertension, September 1, 2001; 38(3): 746 - 752. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. E. Ayala and R. C. Hermida Influence of Parity and Age on Ambulatory Monitored Blood Pressure During Pregnancy Hypertension, September 1, 2001; 38(3): 753 - 758. [Abstract] [Full Text] [PDF] |
||||
|
Hypertension Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2000 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |