Donate Help Contact The AHA Sign In Home
American Heart Association
Hypertension
Search: search_blue_button Advanced Search
Hypertension. 2001;37:185-186

This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jones, D. W.
Right arrow Articles by Taubert, K. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jones, D. W.
Right arrow Articles by Taubert, K. A.

(Hypertension. 2001;37:185.)
© 2001 American Heart Association, Inc.


Editorial

Mercury Sphygmomanometers Should Not be Abandoned: An Advisory Statement From the Council for High Blood Pressure Research, American Heart Association

Daniel W. Jones; Edward D. Frohlich; Carlene M. Grim; Clarence E. Grim; Kathryn A. Taubert; for the Professional Education Committee, Council for High Blood Pressure Research

Correspondence to Daniel Jones, MD, Professor of Medicine, University of Mississippi Medical Center, Division of Hypertension, 2500 North State St, Jackson, MS 39216-4505. E-mail djones{at}medicine.umsmed.edu


*    Introduction
up arrowTop
*Introduction
down arrowReferences
 
In healthcare institutions around this country and around the world, mercury sphygmomanometers are being removed.1 In many situations, the decision to replace the instruments is being made without significant input from involved clinicians or consideration of the health risks that will follow if they are replaced by less accurate devices.

Blood pressure measurement is an important indicator of the current clinical condition of patients and a powerful predictor of future cardiovascular and overall health.2 Blood pressure measurement is often considered "routine" and is often performed by those with the least training. In many institutions, blood pressure measurement is a low priority, with less than ideal quality control related to equipment selection, equipment calibration and repair, and personnel training and performance.

For more than a century, the mercury gravity sphygmomanometer has been the gold standard for indirect measurement of blood pressure. Indeed, the world primary standard for pressure measurement is a mercury manometer. It is a simple, gravity-based unit with easy calibration, infrequent need for repair, and it has been validated in many clinical circumstances against direct intra-arterial blood pressure measurement.3

In recent years, these mercury units have been replaced with aneroid instruments in many institutions and more recently with electronic manometers. Justifications for the replacement of mercury manometers have included concerns about the safety of mercury, concerns about regulations regarding the use of mercury in the workplace, and attempts to eliminate human error involved in the reading of measurements.4 An examination of the evidence around these concerns is necessary before clinicians contribute actively or passively to the replacement of these instruments.

Are mercury manometers dangerous to use in hospital and other clinical settings? Accidental exposure to mercury from sphygmomanometers used in healthcare settings is extremely rare. It is true that there have been a few isolated instances of illness in children from mercury toxicity related to broken elemental mercury-containing instruments used in homes. Most of these occurrences have been related to broken glass thermometers.5 One detailed report has provided data suggesting that volatilized mercury, after spillage of mercury, produced reversible neurological symptoms.6 Nevertheless, modern mercury sphygmomanometers are available in models that prevent accidental spillage of mercury, which essentially eliminates the concern for this rare occurrence.

Is the use of mercury manometers forbidden by regulation in the United States? No. Most regulations related to mercury deal with mercury compounds, such as those used in the manufacture of some automobile batteries. The use of mercury manometers is presently restricted in only a handful of countries.1 None of the healthcare regulatory agencies in the United States, governmental or voluntary, forbid the use of mercury manometers. However, reports of loss of hospital accreditation in the United States (for whatever reasons) have prompted widespread concern. Notwithstanding, mercury instruments are approved and are legal devices in this country, and we believe they should remain so.

Are aneroid or electronic instruments a reliable substitute for mercury manometers? There are 2 crucial issues to consider here: validation and calibration. Although both aneroid and electronic instruments have some advantages of portability and ease of use, few of these instruments have had adequate validation. Still fewer of these instruments are calibrated regularly. To be sure, these instruments have a place in patient management, particularly with respect to their use as home monitoring devices. However, most of these instruments have not been adequately validated over a wide range of blood pressures, ages, and clinical conditions to warrant routine use in hospitals and outpatient settings.7 What is of critical importance is that most manufacturers of aneroid and electronic instruments recommend calibration against a mercury manometer every 6 months. However, few hospitals and clinics have a regular program of evaluation and calibration. Most of these instruments cannot be calibrated without return to the manufacturer.8

Can the use of electronic instruments eliminate human error in blood pressure determination? Certainly, a challenging aspect of human blood pressure determination with a mercury sphygmomanometer is the human error introduced with the hearing and recording of the Korotkoff sounds. Hearing impairment and digit preference are 2 major concerns. Electronic instruments do offer an advantage in this area but still leave ample room for other causes of human error in cuff size determination, placement of the cuff, etc. It is apparent that all human error cannot be eliminated with electronic devices.

Is accurate blood pressure measurement really important? Obviously the answer is yes. Consistent overestimation of blood pressure in the population can be associated with costly overtreatment of hypertension. Consistent underestimation of blood pressure can cost many lives in failing to prevent cardiovascular disease through effective and safe therapy of hypertension.2

There is a constant need for caution in the selection of blood pressure measuring devices. New is not always better. Just as in the selection of medication for elevated blood pressure, evidence should guide our decisions. Sometimes, evidence presents us with unexpected outcomes. We encourage consideration of the same level of evidence in the selection of blood pressure measuring devices as in the selection of drugs and other medical instruments. Clinicians involved in the management of patients with blood pressure problems must accept the responsibility for ensuring adequate instruments are available. If we are passive much longer, the time to act effectively will be past.

Specifically, we recommend that clinicians educate themselves on the instruments available for use in their clinics and hospitals; engage in the process of selection of instruments through dialogue with administrators and through hospital committees; encourage the general use of mercury manometers as the instrument of choice until other instruments are better validated; where aneroid or electronic instruments are used, ensure that instruments are validated through the Association for the Advancement of Medical Instrumentation or a similar organization; ensure a program of regular maintenance and calibration of all instruments. In sites where aneroid or electronic instruments are used exclusively, if mercury instruments cannot be reintroduced for regular use, insist on the use of mercury instruments for calibration of aneroid and electronic instruments; ensure a regular training program for those who measure blood pressure; join the American Heart Association in encouraging studies to validate the safety and reliability of all instruments used for blood pressure determination; and use evidence in determining both safety and reliability of any instrument.

To these ends, the American Heart Association stands ready to relate with any and all organizations wishing to further explore this issue. Throughout 6 published editions on human sphygmomanometry for patients, the American Heart Association has presented updated information on this vital subject. We stand ready to consider any new views and data that are germane to the publication of our next report.


*    Footnotes
 
The opinions expressed in this editorial are not necessarily those of the editor or of the American Heart Association.


*    References
up arrowTop
up arrowIntroduction
*References
 
1. Markandu ND, Whitcher F, Arnold A, Carney C. The mercury sphygmomanometer should be abandoned before it is proscribed. J Hum Hypertens. 2000;14:31–36.[Medline] [Order article via Infotrieve]

2. The sixth report of the joint national committee on prevention, detection, evaluation, and treatment of high blood pressure. Arch Intern Med. 1997;157:2413–2446.[Abstract/Free Full Text]

3. Perloff D, Grim C, Flack J, et al, for the Writing Group. Human blood pressure determination by sphygmomanometry. Circulation. 1993;88:2460–2467.[Free Full Text]

4. Obrien E. Will mercury manometers soon be obsolete? J Hum Hypertens. 1995;9:933–934.[Medline] [Order article via Infotrieve]

5. Langford N, Ferner R. Toxicity of mercury. J Hum Hypertens. 1999;13:651–656.[Medline] [Order article via Infotrieve]

6. Rennie AC, McGregor-Schuerman M, Dale IM, Robinson C, McWilliam R. Mercury poisoning after spillage at home from a sphygmomanometer on loan from hospital. BMJ. 1999;319:366–367.[Free Full Text]

7. Yarrows SA, Brook RD. Measurement variation among twelve electronic home blood pressure monitors. Am J Hypertens. 2000;13:276–282.[Medline] [Order article via Infotrieve]

8. Carney SL, Gillie AH, Green SL, Patterson O, Taylor MS, Smith AJ. Hospital blood pressure measurement: staff and device assessment. J Qual Clin Pract. 1999;19:95–98. [Medline] [Order article via Infotrieve]




This article has been cited by other articles:


Home page
HypertensionHome page
X. Chen, Y. Wang, L. J. Appel, and J. Mi
Impacts of Measurement Protocols on Blood Pressure Tracking From Childhood Into Adulthood: A Metaregression Analysis
Hypertension, March 1, 2008; 51(3): 642 - 649.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
E. S.H. Kim, T. A. Samuels, H.-C. Yeh, M. Abuid, S. S. Marinopoulos, J. M. McCauley, and F. L. Brancati
End-Digit Preference and the Quality of Blood Pressure Monitoring in Diabetic Adults
Diabetes Care, August 1, 2007; 30(8): 1959 - 1963.
[Abstract] [Full Text] [PDF]


Home page
Journal of the American Dental AssociationHome page
W. W. HERMAN, J. L. KONZELMAN JR., and L. M. PRISANT
New national guidelines on hypertension: A summary for dentistry
J Am Dent Assoc, May 1, 2004; 135(5): 576 - 584.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
B. M. Karnath
Accurate Measurement of Blood Pressure
JAMA, June 4, 2003; 289(21): 2792 - 2792.
[Full Text] [PDF]


Home page
JAMAHome page
D. W. Jones, L. J. Appel, S. G. Sheps, E. J. Roccella, and C. Lenfant
Measuring Blood Pressure Accurately: New and Persistent Challenges
JAMA, February 26, 2003; 289(8): 1027 - 1030.
[Full Text] [PDF]


Home page
HypertensionHome page
P. J. Colquitt and D. Jones
Electronic Sphygmomanometers: Are They a Source of Mercury in Hospitals?
Hypertension, March 1, 2002; 39 (3): e21 - e21.
[Full Text] [PDF]


Home page
HypertensionHome page
E. O'Brien, D. W. Jones, E. D. Frohlich, C. M. Grim, C. E. Grim, and K. A. Taubert
Response to the Advisory Statement From the Council for High Blood Pressure Research of the American Heart Association Advocating Retention of Mercury Sphygmomanometers Response
Hypertension, October 1, 2001; 38 (4): e19 - e20.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jones, D. W.
Right arrow Articles by Taubert, K. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jones, D. W.
Right arrow Articles by Taubert, K. A.