(Hypertension. 2001;37:1362.)
© 2001 American Heart Association, Inc.
Scientific Contributions |
From the Laboratory for Cardiovascular Research, Hebrew Rehabilitation Center for Aged Research and Training Institute; and Division on Aging, Harvard Medical School, Boston, Mass.
Correspondence to J. Andrew Taylor, PhD, Laboratory for Cardiovascular Research, Research and Training Institute, Hebrew Rehabilitation Center for Aged, 1200 Centre St, Boston, MA 02131. E-mail ataylor{at}mail.hrca.harvard.edu
| Abstract |
|---|
|
|
|---|
Key Words: arterial pressure carotid arteries ultrasonography
| Introduction |
|---|
|
|
|---|
R-R
interval/
systolic
pressure).4 This estimate
represents an integrated input-output relation and provides
broad insight to baroreflex function. However, it has long been
recognized that baroreceptors respond to deformation not pressure per
se. Early in the last century, Sollman and
Brown5 reported that stretch
of the carotid artery produces bradycardia and hypotension in dogs.
Similar reflex responses in humans derive from proportionalities
between changes in carotid diameter and carotid nerve
firing6 and between the R-R
interval and the frequency of afferent carotid sinus nerve
activation.7 Thus, mechanical
transduction of arterial pressure into carotid stretch and
neural transduction of carotid stretch into vagal outflow are the key
steps in baroreflex regulation that determine the conventional
integrated input-output relation. Both mechanical transduction of pressure and neural transduction of stretch may be profoundly important in pathophysiological conditions. For example, greater carotid vascular stiffness in human hypertension1 would effectively desensitize baroreceptors and depress baroreflex autonomic regulation. Alternatively, in the absence of structural changes, cardiac vagal deficiencies, which can occur early in the progression of diabetes8 and may characterize orthostatic intolerance,3 would reduce neural transduction and blunt baroreflex responses to pressure decreases. However, elucidating either of these processes in humans is difficult. Static measures of basal arterial stiffness can be obtained and are associated with integrated baroreflex gain,1 9 yet they provide no information on dynamic vascular responses to rapid pressure changes10 that usually characterize baroreflex activation. Measures of the neural component of the baroreflex arc are exceedingly rare, because of the difficulty of obtaining recordings of afferent baroreceptor or efferent vagal nervous activity in humans. Nonetheless, the sparse information supports a close relation between baroreflex stimulus and vagal response. Changes in carotid diameter within the cardiac cycle produce proportionate firing of afferent baroreceptive fibers,6 direct stimulation of these afferents produces proportional R-R interval responses,7 and R-R interval changes proportionally with the rate of vagus nerve stimulation.11 These 3 observations suggest that the relation between barosensory vessel diameter and R-R interval may represent the afferent-efferent neural baroreflex arc in humans.
We set out to develop a technique for direct, minimally invasive estimation of both mechanical and neural components of the integrated cardiac-vagal baroreflex in humans. On the basis of the observations outlined above, we measured arterial pressures, common carotid diameters, and R-R intervals during a pharmacological arterial baroreflex stimulus to broaden our ability to assess baroreflex function. Our aim was to determine whether this novel approach of concurrent beat-by-beat measures provides reliable estimates of not only the standard integrated baroreflex gain but also the mechanical transduction of arterial pressure into barosensory vessel stretch and the neural transduction of barosensory vessel stretch into autonomic outflow, facets of baroreflex function difficult to ascertain in humans. Furthermore, we wanted to determine whether application of this technique to physiological and pathophysiological states characterized by alterations in baroreflex function would give unique insight to cardiovascular autonomic regulation in humans.
| Methods |
|---|
|
|
|---|
Protocol
Arterial Pressure and R-R
Interval
Beat-by-beat arterial pressures from a
finger photoplethysmograph (Finapres, Datex-Ohmeda) and a standard
3-lead ECG were recorded continuously. An oscillometric blood
pressure system on the contralateral arm (Dinamap) was used to
calibrate the Finapres against a standard brachial
measure.
Carotid Ultrasonography
Longitudinal B-mode images of a common carotid
artery,
1 cm below the carotid bulb, were obtained using a
high-resolution linear array transducer (7.5 MHz, Hewlett-Packard). The
transducer was placed at 90° to the vessel so that the near and far
wall interfaces were clearly discernible. Commercially available
hardware (PCI Frame Grabber, Datax) and software (CVI Acquisition,
Information Integrity) acquired 30 Hz images to the computer triggered
from the R wave of the ECG. Fifteen consecutive carotid images were
acquired with each trigger to approximate at least one third the
cardiac cycle (ie, 500 ms of a 1500-ms R-R interval or 40-bpm heart
rate) and, therefore, encompass both end-diastolic and
peak-systolic carotid diameters.
Pharmacological Baroreflex Engagement
We used the modified Oxford technique, which involves
a bolus injection of 100 µg of sodium nitroprusside followed in 60
seconds by a bolus of 150 µg of phenylephrine
hydrochloride. Responses of a representative subject
are shown in the top panels of
Figure 1. This technique generally produces an initial
15 mm Hg drop in arterial pressure followed by an
15 mm Hg rise in pressure above resting supine
levels.12 In this particular
subject, arterial pressure only increased
8 mm Hg
above baseline, probably because of effective buffering by pronounced
lengthening of the R-R interval. The advantage of the modified Oxford
technique is that it produces a longer and greater pressure rise than
the more commonly used Oxford technique (phenylephrine
alone). Moreover, arterial baroreflex gain does not differ
if pressure is raised from lower compared with resting
levels13 ; thus, acquisition
of ultrasound images (ie, carotid diameters) once every
2 seconds
did not compromise the ability to make robust baroreflex gain estimates
with the modified Oxford technique (see below, Baroreflex Gain
Estimates). The drug injection sequence was repeated twice to assess
test-retest reliability of baroreflex indices. Trials were separated by
at least 15 minutes to allow full recovery to baseline. A total of 3
trials were necessary to obtain adequate image quality for at least 2
trials.
|
Data Analysis
Hemodynamic Data
Beat-by-beat arterial pressure and ECG
waveforms were digitized to computer at 500 Hz for subsequent offline
analysis with signal processing software (WINDAQ, Dataq). R-R
intervals were derived from the time difference between marks placed on
the peak of the R waves. Systolic and diastolic
pressures were derived from the maximum and the minimum of the
beat-by-beat pressure waveform.
Carotid Diameter
We used image analysis software (CVI
Analysis, Information Integrity) closely conforming to that
described in detail
previously.14 Briefly,
several points in proximity to the edges of the near and far walls were
selected. The software fit a spline that contained 100 points to each
set of preliminary edge points. The direction locally perpendicular to
each spline point was calculated, and the image was interpolated for 6
pixels in either direction perpendicular to the spline. The location
along the interpolated line with the largest sum of first and second
derivatives was then chosen as the best edge point. This process was
repeated for each spline point along the 2 edges. Edge points, which
represent weak edges (ie, points selected at edges with <20%
of the maximum sum of the intensity derivatives of all edge points),
were replaced by linear connections between the nearest strong edge
points. The 2 sets of edge points extracted by the above procedure were
modeled as a pair of parabolas, according to a least square error fit,
in which the 2 parabolas are constrained to have the same curvature.
The diameter of the artery was calculated as the distance between the 2
parabolas. The user-selected preliminary edge points were reused for
successive images and could be moved as a group to compensate for
translational motion of the artery. This reduces variance in the time
series of diameter measurements by as much as a factor of 5 compared
with standard ultrasonic
calipers.15
Association of Carotid Diameters and
Hemodynamic Data
To minimize measurement error in carotid diameter
estimation, we used a 3-diameter moving average
(Figure 1, bottom panels). Custom software associated
diameters to appropriate pressures and R-R intervals. Within a cardiac
cycle, we associated systolic pressure with the largest carotid
diameter and diastolic pressure with the smallest diameter
before systole. We associated the R-R interval with systolic
pressure and systolic diameter after appropriately accounting
for baroreflex delays; pressure and diameter were associated with the
concurrent R-R interval at heart periods >800 ms and the subsequent
R-R interval at heart periods between 500 and 800
ms.16
| Results |
|---|
|
|
|---|
|
Estimate Variance
A Bland-Altman
plot17 of the 3 estimates of
cardiac vagal baroreflex control is shown in
Figure 3. Variability in repeated measures relative to the
mean was comparable for each baroreflex component and the integrated
baroreflex gain, with no systematic bias apparent across gains. The
mean difference between trials was
0.06x103 mm/mm Hg for the mechanical
component, 0.92x10-3ms/mm for the neural
component, and 0.32 ms/mm Hg for integrated baroreflex gain.
Furthermore, a Leveen test for homogeneity of variance between
individual trials18
indicated that measurement variability was no different among the 3
baroreflex gain estimates:
2 mechanical=0.69±0.17,
2 neural=0.56±0.21,
and
2 integrated=0.74±0.16,
(P=0.67).
|
Relations Among Estimates
Simultaneous measures of mechanical
transduction of pressure into stretch near the carotid barosensory area
(mm/mm Hg), neural transduction of stretch into vagal outflow (ms/mm),
and the resulting integrated baroreflex gain (ms/mm Hg) are shown for
1 subject in
Figure 4 (from raw data in
Figure 1). This subject demonstrated a marked increase in
heart period as systolic pressure increased from
106 to
109 mm Hg (right panel), apparently because of nonlinearity in
mechanical pressure transduction (left panel) rather than neural
control (middle panel). In the group as a whole, although mechanical
and neural gains were only modestly related to integrated cardiac-vagal
baroreflex gain (r=0.53,
P=0.04, and
r=0.35,
P=0.18), the simple product
of the 2 gains was almost equivalent to the integrated gain
(Figure 5). Thus, in these young healthy subjects, neither
single component accounts for the integrated baroreflex gain; instead,
mechanical and neural components act in concert to produce the
integrated baroreflex
response.
|
|
| Discussion |
|---|
|
|
|---|
Technical Considerations
The addition of beat-by-beat carotid diameters to
arterial pressure and heart period requires acquisition,
maintenance, and analysis of B-mode ultrasound images.
Though baseline diameters were not different between trials (6.42±0.14
versus 6.41±0.13; P=0.76),
indicating our image acquisition was reliable, we found that
maintenance of image quality throughout the pharmacological
intervention can be difficult; necessitating 3 trials to
consistently obtain 2 complete trials with adequate images for
analysis in all subjects. Despite this difficulty, these data
reliably characterize the entire range of barosensory vessel engagement
during dynamic pressure changes that, to date, have not been described
in humans. Other technologies for carotid diameter measurement are
available.9 19
However, they are limited by an inability to estimate carotid diameters
for more than a short duration, usually
5 to 10 seconds. (The
duration of the pressure rise in our subjects averaged 76 seconds.)
These processes reduce ultrasound information to only a small portion
of the signal, producing diameter estimates with greater frequency
resolution than B-mode imaging, yet no greater
accuracy.15 It should be
noted that our technique is affected by computer hardware limitations.
As
Figure 1 shows, after the initial few cardiac cycles, image
sets were only acquired on approximately every other cardiac cycle
because of the speed of the hard drive. Although we were not able to
acquire carotid diameter data for every cardiac cycle for the current
data, we acquired diameters for at least 60 cardiac cycles,
encompassing the entire period of dynamic baroreceptor activation.
Moreover, we have recently begun to use a high-speed hard drive and now
acquire diameter data on nearly 100% of all cardiac cycles.
Additionally, B-mode ultrasonography allows both real-time and post-hoc
evaluation of data quality during a procedure that markedly alters the
diameter of a highly elastic vessel. Pulsatile carotid diameter changes
are
15%,9 20
and we observed an additional
15% change in systolic
diameter during bolus vasoactive drug infusion in our subjects. These
large changes can easily alter the angle of ultrasound insonation and
cause misestimation of diameter. However, B-mode imaging provides
direct visual feedback to both ultrasound operator and image analyst to
identify shifts that would create erroneous diameter changes. This
provides a level of confidence in the data that compensates for the
level of difficulty in its acquisition.
Our estimates of mechanical pressure transduction, neural
afferent-efferent activation, and integrated baroreflex gain were as
reproducible, or more so, than other techniques. Reported coefficient
of variations for cardiac-vagal baroreflex gain are
29% for
Valsalvas maneuver,21 40%
for the spontaneous sequence method, and 52% for both frequency domain
and Oxford techniques.22 We
found a coefficient of variation of 23% for standard integrated
baroreflex gain, slightly less than, but not significantly different
from 32% for the mechanical component and 26% for the neural
component. Although a third trial may have reduced the error of our
estimates and may be necessary in individuals with lower baroreflex
gain, 2 trials resulted in comparable variance without any systematic
bias in each component and integrated gain. Thus, reliance on
ultrasound-derived, beat-by-beat carotid diameters for our 2 baroreflex
component estimates introduces no greater trial-to-trial variability to
baroreflex gain assessments via the modified Oxford
technique.
Physiological
Considerations
We devised an approach to baroreflex physiology based
on established findings that support a line of evidence for this
technique. Arterial baroreceptive afferents are primarily
responsive to pressure-related
stretch.5 6 In
their classic work, Kober and
Arndt20 showed that changes
in transmural arterial pressure were linearly related to
changes in carotid diameter, suggesting carotid arterial
pressure may be used as a surrogate for arterial diameter.
However, significant deformation of barosensory areas in
humans23 24 and
altered afferent baroreceptor activity in
dogs25 may occur in the
absence of measurable arterial pressure changes. Therefore,
pressure may not index the true arterial baroreceptor
stimulus. In fact, the prevailing arterial pressure as well
as afferent nervous activity appear to be determined by barosensory
vessel diameter. In patients after endarterectomy,
those with increased carotid sinus diameter had greater carotid sinus
nerve activity and lower postoperative blood
pressure.26 Thus, excising
carotid tissue altered the relation between pressure and diameter but
not that between diameter and nervous activity. Although the only human
data demonstrate a simple proportionality between carotid sinus
dimensions and integrated carotid sinus nerve activity within the
cardiac cycle,6 animal data
suggest a linear proportionality applies throughout broader pressure
ranges.27 28
These data suggest that carotid diameter may serve as an appropriate
index of the arterial baroreceptor stimulus and resulting
afferent activity.
Afferent baroreceptor stimulation generates R-R interval responses that are proportional in humans7 and linear in cats.29 Although cardiac chronotropy can also be modulated by cardiovascular sympathetic afferents,30 31 rapid heart period responses to baroreflex engagement in humans is likely to be predominantly mediated through efferent vagal activity,2 because cardiac sympathetic activity tends to have longer lag time.32 Moreover, though acute and chronic cardiac sympathetic blockade may augment baroreflex sensitivity,33 baroreflex-mediated heart period slowing does not occur without intact cardiac parasympathetic activation.34 35 Thus, the R-R interval provides a commonly accepted estimate of the cardiac vagal efferent response to arterial baroreflex engagement.
Assessing each of the above steps in the baroreflex control of arterial pressure is difficult in the intact human. However, given that barosensory vessel stretch is a key determinant of reflex responses, we thought the simple addition of a diameter estimate would provide incisive information on baroreflex physiology. The standard relation of R-R interval to arterial pressure is a global estimate of the cardiac vagal limb of systemic control. We derived 2 additional relations: arterial pressure to carotid diameter and carotid diameter to R-R interval. The first provides information on the mechanical transduction of the controlled variable to the input variable for baroreflex engagement. The second provides a global index of the complex integration of baroreceptor afferent activation and CNS efferent outflow, resulting in cardiac slowing or acceleration. Thus, 2 distinct components that determine integrated baroreflex gain can be assessed.
It should be noted that a linear model is commonly used to estimate cardiac-vagal baroreflex gain. However, baroreflex-mediated R-R interval responses to arterial pressure changes demonstrate a clear sigmoid pattern; R-R interval responses are minimal below threshold and above saturation pressures and are maximal at some point within this range.36 Following convention, we merely applied a linear model to the relations between threshold and saturation.12 When examining the data presented in Figure 4, it is apparent that this approach does not capture some aspects of the complex, nonlinear, cascade of events linking arterial pressure changes to R-R interval responses. This subject demonstrated a clear nonlinearity in the mechanical component, although these points lie within the most linear region of the integrated baroreflex response. Thus, the most linear range of the integrated baroreflex is likely the result of the interplay between nonlinear and linear mechanical and neural components of the reflex arc. Although using a sigmoid model would provide insight to this intriguing aspect of baroreflex physiology, we have shown previously that not all, nor all relations, will consistently demonstrate the entire sigmoid range with the modified Oxford testing. However, a linear model applied to the region between threshold and saturation produces a robust estimate of baroreflex gain, the most important aspect of pressure regulation.37
Our linear estimates of mechanical pressure transduction and
neural afferent-efferent activation were related strongly to integrated
baroreflex gain within subjects but only modestly among subjects. The
simple product of the components almost equaled the measured
integrated gain for each trial. This may not seem surprising, but each
slope was determined independently and thus no mathematical dependency
existed. Therefore, the strong relationship indicates that these 2
components encompass the primary determinants of arterial
baroreflex gain. There was
13% of the actual measured integrated
gain not accounted for, indicating there are other aspects of
baroreflex function not explained by these measures. In the group as a
whole, the neural component was not significantly related to integrated
gain, whereas the mechanical component more strongly predicted
integrated gain. Data from Lage et
al1 on basal measures of
carotid compliance show a similar relation to baroreflex gain in
normotensive and hypertensive adults. However, our laboratory and
others have reported that basal measures of carotid stiffness were more
strongly related to integrated baroreflex gain in young adults
(r=0.78 to
0.82).9 38 This
might be explained by the fact that stiffness measures are not pressure
dependent whereas both our mechanical component and compliance measures
are pressure dependent. However, our technique provides information
relevant to the dynamic, and possibly more complex, mechanical
transduction of pressure throughout the responsive range of the
baroreflex.
Clinical Implications
Given our homogeneous study population, it
may not be surprising that neither mechanical pressure transduction nor
neural baroreflex gain were strongly associated with integrated
baroreflex gain. In young healthy adults without arterial
stiffening or autonomic neuropathy, it is quite possible
that both mechanical and neural components play equally important roles
in baroreflex pressure regulation. However, insight to baroreflex
function may be gained in populations known to have altered vascular
mechanics, neurological lesions, or depressed baroreflex function of
unknown origin. For example, coronary artery disease patients
are known to have depressed integrated baroreflex gain that is presumed
to be parasympathetic in
origin.2 However, preliminary
data from our laboratory on 3 adults with coronary artery
disease shows the previously described decrement in integrated
baroreflex gain compared with 4 age-matched healthy adults
(Figure 6), yet their neural baroreflex component is similar.
This would suggest that autonomic neural function is intact and that
vascular structural change underlies blunted baroreflex function in
coronary disease. However, the use in a clinical setting would
be dependent on establishing normative data for each baroreflex
component, which at present does not exist.
|
This work defined and tested an approach to baroreflex physiology. Our findings, as well as the above preliminary data, demonstrate that important information on autonomic physiology may be derived with appropriate application of our technique. Although the standard description of baroreflex function from heart period and arterial pressure relations provides broad insight to autonomic control, the simple addition of a single key physiological variable may provide more mechanistic insight. Assessment of the mechanical and neural baroreflex components via our technique may provide critical understanding of autonomic function in human health and disease.
| Acknowledgments |
|---|
Received July 13, 2000; first decision August 9, 2000; accepted December 1, 2000.
| References |
|---|
|
|
|---|
2. Eckberg DL, Drabinsky M, Braunwald E. Defective cardiac parasympathetic control in patients with heart disease. N Engl J Med. 1971;285:877883.
3. Bennett T, Hosking DJ, Hampton JR. Cardiovascular responses to graded reductions of central blood volume in normal subjects and in patients with diabetes mellitus. Clin Sci. 1980;58:193200.[Medline] [Order article via Infotrieve]
4. Sagawa K. Concerning "gain." Am J Physiol. 1978;235:H117.
5. Sollman T, Brown ED. The blood pressure fall produced by traction on the carotid artery. Am J Physiol. 1912;30:88104.
6. Angell-James JE, Lumley JS. Changes in the mechanical properties of the carotid sinus region and carotid sinus nerve activity in patients undergoing carotid endarterectomy. J Physiol (Lond). 1975;244:80P-81P.
7. Borst C, Karemaker JM, Dunning AJ, Bouman LN, Wagner J. Frequency limitation in the human baroreceptor reflex. J Auton Nerv Syst. 1983;9:381397.[Medline] [Order article via Infotrieve]
8. Veglio M, Carpano-Maglioli P, Tonda L, Quadri R, Giannella R, Rosa C, Fonzo D. Autonomic neuropathy in non-insulin-dependent diabetic patients: correlation with age, sex, duration and metabolic control of diabetes. Diabete Metab. 1990;16:200206.[Medline] [Order article via Infotrieve]
9.
Bonyhay I, Jokkel
G, Kollai M. Relation between baroreflex sensitivity and carotid artery
elasticity in healthy humans. Am J
Physiol. 1996;271:H1139H1144.
10. Taylor MG. The elastic properties of arteries in relation to the physiological functions of the arterial system. Gastroenterology. 1967;52:358363.[Medline] [Order article via Infotrieve]
11. Carlsten A, Folkow B, Hamberger C-A. Cardiovascular effects of direct vagal stimulation in man. Acta Physiol Scand. 1957;41:6876.[Medline] [Order article via Infotrieve]
12. Ebert TJ. Differential effects of nitrous oxide on baroreflex control of heart rate and peripheral sympathetic nerve activity in humans. Anesthesiology. 1990;72:1622.[Medline] [Order article via Infotrieve]
13. Rudas L, Crossman AA, Morillo CA, Halliwill JR, Tahvanainen KU, Kuusela TA, Eckberg DL. Human sympathetic and vagal baroreflex responses to sequential nitroprusside and phenylephrine. Am J Physiol. 1999;276:H1691H1698.
14. Stadler RW, Karl WC, Lees RS. New methods for arterial diameter measurement from B-mode images. Ultrasound Med Biol. 1996;22:2534.[Medline] [Order article via Infotrieve]
15. Stadler RW, Taylor JA, Lees RS. Comparison of B-mode, M-mode and echo tracking methods for measurement of the arterial distension waveform. Ultrasound Med and Biol. 1997;23:879887.[Medline] [Order article via Infotrieve]
16. Eckberg DL, Eckberg MJ. Human sinus node responses to repetitive, ramped carotid baroreceptor stimuli. Am J Physiol. 1982;242:H638H644.
17. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307310.[Medline] [Order article via Infotrieve]
18. Glass GV, Hopkins KD. Statistical Methods in Education and Psychology. 3rd ed. Boston, Mass: Allyn & Bacon; 1996.
19.
Barth JD,
Blankenhorn DH, Wickham E, Lai JY, Chin HP, Selzer RH. Quantitative
ultrasound pulsation study in human carotid artery disease.
Arteriosclerosis. 1988;8:778781.
20. Kober G, Arndt JO. Pressure-diameter relationship in the common carotid artery of conscious man. Pflugers Arch. 1970;314:2739.[Medline] [Order article via Infotrieve]
21. Lord SW, Clayton RH, Hall MC, Gray JC, Murray A, McComb JM, Kenny RA. Reproducibility of three different methods of measuring baroreflex sensitivity in normal subjects. Clin Sci (Colch). 1998;95:575581.[Medline] [Order article via Infotrieve]
22. Davies LC, Francis D, Jurak P, Kara T, Piepoli M, Coats AJ. Reproducibility of methods for assessing baroreflex sensitivity in normal controls and in patients with chronic heart failure. Clin Sci (Colch). 1999;97:515522.[Medline] [Order article via Infotrieve]
23. Lacolley PJ, Pannier BM, Slama MA, Cuche JL, Hoeks AP, Laurent S, London GM, Safar ME. Carotid arterial haemodynamics after mild degrees of lower-body negative pressure in man. Clin Sci (Colch). 1992;83:535540.[Medline] [Order article via Infotrieve]
24.
Taylor JA,
Halliwill JR, Brown TE, Hayano J, Eckberg DL. Non-hypotensive
hypovolemia reduces ascending aortic dimensions in humans.
J Physiol. 1995;483:1:289298.
25.
Hajduczok G,
Chapleau MW, Abboud FM. Rheoreceptors in the carotid sinus of dog.
Proc Natl Acad Sci
U S A. 1988;85:73997403.
26. Angell-James JE, Lumley JS. The effects of carotid endarterectomy on the mechanical properties of the carotid sinus and carotid sinus nerve activity in atherosclerotic patients. Br J Surg. 1974;61:805810.[Medline] [Order article via Infotrieve]
27. Hartikainen J, Ahonen E, Nevalainen T, Sikanen A, Hakumaki M. Haemodynamic information encoded in the aortic baroreceptor discharge during haemorrhage. Acta Physiol Scand. 1990;140:181189.[Medline] [Order article via Infotrieve]
28. Landgren S. The baroceptor activity in the carotid sinus nerve and the distensibility of the sinus wall. Acta Physiol Scand. 1952;26:3556.[Medline] [Order article via Infotrieve]
29. Kunze DL. Reflex discharge patterns of cardiac vagal efferent fibres. J Physiol (Lond). 1972;222:115.
30.
Gnecchi Ruscone
T, Lombardi F, Malfatto G, Malliani A. Attenuation of baroreceptive
mechanisms by cardiovascular sympathetic afferent
fibers. Am J Physiol. 1987;253:H787H791.
31.
Schwartz PJ,
Pagani M, Lombardi F, Malliani A, Brown AM. A cardiocardiac
sympathovagal reflex in the cat. Circ
Res. 1973;32:215220.
32. Samaan A. The antogonistic cardiac nerves and heart rate. J Physiol. 1935;83:332340.
33. Floras JS, Jones JV, Hassan MO, Sleight P. Effects of acute and chronic beta-adrenoceptor blockade on baroreflex sensitivity in humans. J Auton Nerv Syst. 1988;25:8794.[Medline] [Order article via Infotrieve]
34.
Pickering TG,
Gribbin B, Petersen ES, Cunningham DJ, Sleight P. Effects of autonomic
blockade on the baroreflex in man at rest and during exercise.
Circ Res. 1972;30:177185.
35.
Sullebarger JT,
Liang CS, Woolf PD, Willick AE, Richeson JF. Comparison of
phenylephrine bolus and infusion methods in baroreflex
measurements. J Appl
Physiol. 1990;69:962967.
36.
Korner PI, Shaw
J, West MJ, Oliver JR. Central nervous system control of baroreceptor
reflexes in the rabbit. Circ
Res. 1972;31:637652.
37. Farquhar WB, Freeman R, Hunt BE, Darling SE, Taylor JA. The human arterial baroreflex: can a simple line adequately model a sigmoid relation? Physiologist. 2000;43:281. Abstract.
38. Williams TD, OMahony D, Green A, Taylor JA. Spontaneous baroreflex indices do not correlate to carotid pulsatile elasticity. FASEB J. 1998;12:A688. Abstract.
This article has been cited by other articles:
![]() |
K. D. Monahan A new answer to an old question: does ageing modify baroreflex control of vascular sympathetic outflow in humans? J. Physiol., May 1, 2009; 587(9): 1857 - 1857. [Full Text] [PDF] |
||||
![]() |
Pét. Studinger, R. Goldstein, and J. A. Taylor Age- and fitness-related alterations in vascular sympathetic control J. Physiol., May 1, 2009; 587(9): 2049 - 2057. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Deley, G. Picard, and J. A. Taylor Arterial Baroreflex Control of Cardiac Vagal Outflow in Older Individuals Can Be Enhanced by Aerobic Exercise Training Hypertension, May 1, 2009; 53(5): 826 - 832. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Deley, R. D. Lipman, J. P. Kannam, C. Bartolini, and J. A. Taylor Stress responses and baroreflex function in coronary disease J Appl Physiol, February 1, 2009; 106(2): 576 - 581. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. E. Hunt, R. Tamisier, G. S. Gilmartin, M. Curley, A. Anand, and J. W. Weiss Baroreflex responsiveness during ventilatory acclimatization in humans Am J Physiol Heart Circ Physiol, October 1, 2008; 295(4): H1794 - H1801. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Ptaszynski, T. Klingenheben, B. Gerritse, and L. Kornet Risk stratification after myocardial infarction: a new method of determining the neural component of the baroreflex is potentially more discriminative in distinguishing patients at high and low risk for arrhythmias Europace, February 1, 2008; 10(2): 227 - 234. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Studinger, R. Goldstein, and J. A. Taylor Mechanical and neural contributions to hysteresis in the cardiac vagal limb of the arterial baroreflex J. Physiol., September 15, 2007; 583(3): 1041 - 1048. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Hesse, N. Charkoudian, Z. Liu, M. J. Joyner, and J. H. Eisenach Baroreflex Sensitivity Inversely Correlates With Ambulatory Blood Pressure in Healthy Normotensive Humans Hypertension, July 1, 2007; 50(1): 41 - 46. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Olufsen, H. T. Tran, J. T. Ottesen, Research Experiences for Undergraduates Program, L. A. Lipsitz, and V. Novak Modeling baroreflex regulation of heart rate during orthostatic stress Am J Physiol Regulatory Integrative Comp Physiol, November 1, 2006; 291(5): R1355 - R1368. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. E. Alvarez, B. M. Davy, T. P. Ballard, S. D. Beske, and K. P. Davy Weight loss increases cardiovagal baroreflex function in obese young and older men Am J Physiol Endocrinol Metab, October 1, 2005; 289(4): E665 - E669. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Lenard, P. Studinger, B. Mersich, G. Pavlik, and M. Kollai Cardiovagal autonomic function in sedentary and trained offspring of hypertensive parents J. Physiol., June 15, 2005; 565(3): 1031 - 1038. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. E. Hunt and W. B. Farquhar Nonlinearities and asymmetries of the human cardiovagal baroreflex Am J Physiol Regulatory Integrative Comp Physiol, May 1, 2005; 288(5): R1339 - R1346. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Lenard, P. Studinger, B. Mersich, L. Kocsis, and M. Kollai Maturation of Cardiovagal Autonomic Function From Childhood to Young Adult Age Circulation, October 19, 2004; 110(16): 2307 - 2312. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Lipman, J. K. Salisbury, and J. A. Taylor Spontaneous Indices Are Inconsistent With Arterial Baroreflex Gain Hypertension, October 1, 2003; 42(4): 481 - 487. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Studinger, Z. Lenard, Z. Kovats, L. Kocsis, and M. Kollai Static and dynamic changes in carotid artery diameter in humans during and after strenuous exercise J. Physiol., July 15, 2003; 550(2): 575 - 583. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Mukai, M. Gagnon, I. Iloputaife, J. W. Hamner, and L. A. Lipsitz Effect of Systolic Blood Pressure and Carotid Stiffness on Baroreflex Gain in Elderly Subjects J. Gerontol. A Biol. Sci. Med. Sci., July 1, 2003; 58(7): M626 - 630. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Lipman, P. Grossman, S. E. Bridges, J.W. Hamner, and J. A. Taylor Mental Stress Response, Arterial Stiffness, and Baroreflex Sensitivity in Healthy Aging J. Gerontol. A Biol. Sci. Med. Sci., July 1, 2002; 57(7): B279 - 284. [Abstract] [Full Text] |
||||
![]() |
P. Kaushal and J. A. Taylor Inter-relations among declines in arterial distensibility, baroreflex function and respiratory sinus arrhythmia J. Am. Coll. Cardiol., May 1, 2002; 39(9): 1524 - 1530. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Kingwell, J. D. Cameron, A. M. Dart, K. D. Monahan, H. Tanaka, F. A. Dinenno, and D. R. Seals Large Artery Stiffness and Baroreflex Function Response Circulation, February 26, 2002; 105 (8): e56 - e56. [Full Text] [PDF] |
||||
![]() |
K. D. Monahan, H. Tanaka, F. A. Dinenno, and D. R. Seals Central Arterial Compliance Is Associated With Age- and Habitual Exercise-Related Differences in Cardiovagal Baroreflex Sensitivity Circulation, October 2, 2001; 104(14): 1627 - 1632. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Hypertension Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2001 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |