Donate Help Contact The AHA Sign In Home
American Heart Association
Hypertension
Search: search_blue_button Advanced Search
Hypertension. 2002;39:963-968
doi: 10.1161/01.HYP.0000016920.96457.7C
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Manning, T. S.
Right arrow Articles by Izzo, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Manning, T. S.
Right arrow Articles by Izzo, J. L., Jr
Related Collections
Right arrow Pulmonary biology and circulation
Right arrow Coronary circulation

(Hypertension. 2002;39:963.)
© 2002 American Heart Association, Inc.


Scientific Contributions

Validity and Reliability of Diastolic Pulse Contour Analysis (Windkessel Model) in Humans

Timothy S. Manning; Barbara E. Shykoff; Joseph L. Izzo, Jr

From the Division of Clinical Pharmacology, Department of Medicine, State University of New York at Buffalo (T.S.M., J.L.I.), NY; and Biomedical Research Department, Navy Experimental Diving Unit, Naval Sea Systems Command (B.E.S.), Panama City, Fla.

Correspondence to J.L. Izzo, Jr, MD, State University of New York at Buffalo, Division of Clinical Pharmacology, 3 Gates Circle, Buffalo, NY 14209. E-mail jizzo{at}acsu.buffalo.edu


*    Abstract
up arrowTop
*Abstract
down arrowIntroduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
The present study assessed (1) the impact of the measurement site (lower versus upper extremity) on the corresponding compliance variables and (2) the overall reliability of diastolic pulse contour (Windkessel-derived) analysis in normal and hypertensive subjects. Arterial tonograms were recorded in the supine position from the radial and posterior tibial arteries in 20 normotensive (116±12/68±8 mm Hg) and 27 essential hypertensive subjects (160±16/94±14 mm Hg). Ensemble-averaged data for each subject were fitted to a first-order lumped-parameter model (basic Windkessel) to compute whole-body arterial compliance (CA) and to a third-order lumped-parameter model (modified Windkessel) to compute proximal compliance (C1) and distal compliance (C2). Despite high-fidelity waveforms in each subject, the first-order Windkessel model did not yield interpretable (positive) values for CA in 50% of normotensives and 41% of hypertensives, whereas the third-order model failed to yield interpretable C1 or C2 results in 15% of normotensives and 41% of hypertensives. No between-site correlations were found for the first-order time constant, 2 of the 3 third-order model curve-fitting constants, or CA, C1, or C2 (P>0.50). Mean values for all 3 compliance variables were higher for the leg than the arm (P<0.05 each). We conclude that differences in Windkessel-derived compliance values in the arm and leg invalidate whole-body model assumptions and suggest a strong influence of regional circulatory properties. The validity and utility of Windkessel-derived variables is further diminished by the absence of between-site correlations and the common occurrence of uninterpretable values in hypertensive subjects.


Key Words: diastole • compliance • models, statistical • plethysmography • hemodynamics


*    Introduction
up arrowTop
up arrowAbstract
*Introduction
down arrowMethods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Increased stiffness (decreased compliance) of the aorta and large blood vessels is associated with wide pulse pressure, systolic hypertension, and increased cardiovascular risk.13 Because wide pulse pressure and systolic hypertension are late manifestations of the arteriosclerotic process, there is significant interest in the development of more sensitive compliance measurements that can detect premature vascular stiffening at an earlier stage of the process. Our laboratory has undertaken a systematic analysis of 3 of these noninvasive compliance methods: systolic pulse contour analysis, plethysmography, and diastolic pulse contour analysis.4 Using these 3 methods in over 100 subjects, we have found that the respective compliance and reflectance values correlate poorly across methods and have concluded that either the biologic information that each method provides is intrinsically different or that major methodological artifacts exist.4

The first method that we have subjected to additional methodological validation is diastolic pulse contour analysis.58 Diastolic pulse contour analysis is based on the assumption that the circulation can be represented by 1 (first-order model) or 2 (third-order model, including an interposed inertance function) capacitors arranged in parallel with a resistor (Figure 1). In these models, vascular elastic recoil (compliance) is represented by the capacitor(s). By fitting the diastolic decay portion of an individual’s arterial waveform to a first-order model (basic Windkessel) or third-order model (modified Windkessel), compliance variables can, theoretically, be derived.



View larger version (12K):
[in this window]
[in a new window]
 
Figure 1. Electrical analog of the first-order Windkessel model (A) and the third-order Windkessel model (B). v indicates voltage; i, current; CA, aortic compliance; R, resistance; L, inductance; C1, large artery compliance; C2, small artery compliance.

The specific purpose of the present studies was to address issues of validity and reliability of Windkessel-derived compliance variables. We tested a specific assumption of this lumped-parameter model: that compliance estimates obtained from all peripheral measurement sites should be equal.6,7 Different compliance estimates obtained from 2 different sites would imply that regional, as well as systemic, factors influence the results. We also investigated the reliability of the system. This last issue is significant because analysis criteria and clinical reliability have not been published during the development of existing proprietary systems that measure arterial compliance.


*    Methods
up arrowTop
up arrowAbstract
up arrowIntroduction
*Methods
down arrowResults
down arrowDiscussion
down arrowReferences
 
Subjects
The study was approved by an institutional review committee, and the subjects gave written informed consent. The study procedures followed were in accordance with institutional guidelines. A sample-size calculation was performed before the study. Based on an effect size equal to 0.5, an {alpha} level equal to 0.05 for a nondirectional test and 1-ß equal to 0.9, the required sample size is approximately 44 subjects. Twenty normotensive subjects (median age 35, range 26 to 79 years) and 27 hypertensive subjects (median age 56, range 43 to 78 years) volunteered for testing. Systolic blood pressure ranged from 96 to 136 mm Hg (mean±SD 116±12 mm Hg) in the normotensive subjects and from 142 to 194 mm Hg (mean±SD 160±16 mm Hg) in the hypertensive subjects. Diastolic blood pressure ranged from 52 to 84 mm Hg (mean±SD 68±8 mm Hg) in the normotensive subjects and from 70 to 118 mm Hg (mean±SD 94±14 mm Hg) in the hypertensive subjects.

Waveform Acquisition
High-fidelity pressure waveforms were obtained noninvasively from the radial and posterior tibial artery by applanation tonometry using a Millar tonometer (Millar Instruments, Inc). The SphygmoCor Blood Pressure Analysis System (PWV Medical, Ltd) was used to amplify the signal and ensemble average the waveform data. Applanation tonometry can be used to record pressure waveforms from any peripheral artery that can be supported by a bony structure. Gently flattening but not collapsing an artery with a tonometer balances circumferential forces in the arterial wall, and the resulting contact force between the artery and the tonometer is equal to intra-arterial pressure.9 To minimize the effects of movement artifact on wave morphology, pressure waveforms were first assessed visually by a technician and then submitted to analysis by the SphygmoCor software, which reports a quality control parameter for diastolic waveform variability. If diastolic waveform variability exceeded 10%, new data were obtained immediately. Pressure waveforms that qualified for data analysis were ensemble-averaged over 11 seconds.

Subjects were supine for all measurements, which were obtained from the right side of the body. Brachial blood pressure was measured on the right arm by auscultation before each tonometry measurement. The order of tonometry measurements was alternated among subjects.

First-Order Model (Basic Windkessel)
The basic Windkessel model, a first-order lumped parameter model, assumes that the time constant ({tau}) of the monoexponential pressure decay is determined by the product of systemic vascular resistance and aortic compliance.8 In the electrical analogue (Figure 1A), voltage (v) is analogous to pressure in the aorta, the capacitor (CA) to whole-body arterial compliance, electrical current (i) to blood flow, and the resistor (R) to systemic vascular resistance. The standard first-order model equation for diastolic pressure (voltage) as a function of time is Down


where (A1+A3) represents end-systolic pressure, A3 is mean circulatory pressure and t is time. The fitted parameter of interest is the time constant ({tau}). When the resistance (R) is known, the whole-body arterial compliance is calculated as Down


Third-Order Model (Modified Windkessel Model)
The third-order lumped-parameter model57 assumes that compliance of the arterial system can be partitioned into central and distal compartments, where central compliance is distinct from distal compliance. In the electrical analogue (Figure 1B), voltage (v) is analogous to mean pressure in the aorta, the first capacitor (C1) to central, proximal, or large artery compliance, electrical current (i) to blood flow, inductance (L) to inertance of a column of blood, the second capacitor (C2) to distal or small artery compliance, and the resistor (R) to systemic vascular resistance.6,7 The third-order model equation for diastolic pressure (voltage) as a function of time isDown


The first term of the equation (A) is derived from the exponential decay of the entire diastolic waveform. The second term (B) is a decaying sinusoid function; the decaying sinusoid accounts for the dicrotic notch and the subsequent damped oscillations. The constants A1, A3, and A6 may vary between measurement sites.57 In the standard model, the constants A2, A4, and A5 should not vary between measurement sites because they are intended to represent the physical structure of the electrical analogue. Constants A2 and A4 are damping constants, whereas A5 is the frequency of oscillation. C1 and C2 were calculated using the following equations:Down Down




In both the first- and third-order model equations, R is an estimate of systemic vascular resistance and demonstrates the high degree of theoretical dependence of C2 on R. For this study, it was not necessary to calculate R because intraindividual comparisons were used; accordingly, an arbitrary constant R value of 1500 dyne · s · cm-5 was used to calculate CA, C1, and C2 at each site.

Data and Statistical Analysis
In both models, the beginning of diastole was defined as the lowest point of the dicrotic notch (ie, the point after which the pressure began to rise again before decaying exponentially). The end of diastole was defined as the point where the diastolic pressure was no longer monotonically decreasing. The curve-fitting constants for each model were estimated by an iterative procedure using Marquardt’s algorithm (nonlinear regression). Curve fits were accepted if the coefficients were significantly different from zero (P<0.05). The variables CA, C1, and C2 were calculated using Eq. 2, 4, and 5, respectively. Only data sets where both radial and posterior tibial artery waveforms could be fitted were used.

The {chi}2 statistic was used to test equality of proportions for the first- and third-order models. Pearson correlation coefficients were calculated to assess the linear relationship between the radial and posterior tibial sites for time constant ({tau}) (first-order model), curve-fitting constants A2, A4, and A5 (third-order model), and the model parameter variables CA, C1, and C2. Bland-Altman plots10 were created to quantify the agreement of CA, C1, and C2 values between sites. Means for each variable were compared between measurement sites using paired t tests ({alpha}=0.05). For hypothesis testing, effect size (partial ETA squared) was calculated using the following equation:11 Down


where dfh denotes degrees of freedom for hypothesis and dfe denotes degrees of freedom for error. The values used to characterize small, medium, and large effect sizes are 0.01, 0.06, and 0.14, respectively.11 For this study, {eta}2p represents the proportion of the total variability attributable to choosing the posterior tibial artery as a measurement site to estimate model parameters CA, C1, and C2.


*    Results
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
*Results
down arrowDiscussion
down arrowReferences
 
Waveforms obtained from the radial artery were distinctly different from corresponding waveforms obtained from the posterior tibial artery (Figure 2), as expected. Coefficients of variation of ensemble-averaged blood pressures within a given individual were less than 5% (radial artery 3.7±1.7%, posterior tibial artery 4.2±2.2%). The mean values, standard deviations, and correlation coefficients for the first-order time constant ({tau}), third-order curve fitting constants (A2, A4, and A5), and each model’s compliance estimates (CA, C1, and C2) are presented in Table 1. CA, C1, and C2 estimates are presented graphically in Figures 3A, 4A, and 5A, respectively.



View larger version (10K):
[in this window]
[in a new window]
 
Figure 2. Characteristic waveforms from radial artery (A) and the posterior tibial artery (B) of a healthy normotensive subject. Arrow denotes a perturbation present in the radial artery but not in the posterior tibial artery, probably representing a wave reflection.


View this table:
[in this window]
[in a new window]
 
Table 1. Curve-Fitting Constants and Model Parameter Compliance Values for Individuals in Whom First and Third-Order Models Could Be Fit



View larger version (20K):
[in this window]
[in a new window]
 
Figure 3. Scatter plot (A) and Bland-Altman plot (B) for the posterior tibial and radial aortic compliance estimate. The solid line in A is the line of identity. CA indicates aortic compliance.



View larger version (15K):
[in this window]
[in a new window]
 
Figure 4. Scatter plot (A) and Bland-Altman plot (B) for the posterior tibial and radial large artery compliance estimate. The solid line in A is the line of identity. C1 indicates large artery compliance.



View larger version (16K):
[in this window]
[in a new window]
 
Figure 5. Scatter plot (A) and Bland-Altman plot (B) for the posterior tibial and radial small artery compliance estimate. The solid line in A is the line of identity. C2 indicates small artery compliance.

Data Correspondence to Model
As shown in Table 2, diastolic waveforms from 11 of 27 hypertensive subjects and from 10 of 20 normotensive subjects could not be described adequately by the first-order model. Waveforms from 11 of 27 hypertensive subjects (not the same individuals) and 3 of 20 normotensive subjects could not be described adequately by the third-order model. The third-order model fit the diastolic waveform data better than the first-order model ({chi}2[1]=13.55, P<0.05). Within the normotensive and hypertensive groups, the ability of the first- and third-order models to fit the data were independent of blood pressure and age. The lack of fit in either model was not related to the nominal quality control parameters from the SphygmoCor system, which did not eliminate any tracings from further analysis.


View this table:
[in this window]
[in a new window]
 
Table 2. Descriptive Data for First-Order and Third-Order Models

Time Constant (First-Order Model)
The correlation coefficient between sites for {tau} was not statistically significant (P=0.97), and a significant difference in mean values was observed between the radial and posterior tibial artery (P=0.027, power=0.62, =0.18).

A2, A4, and A5 (Third-Order Model)
The correlation coefficients between sites for A2 and A4 were not statistically significant (A2 P=0.08, A4 P=0.72), whereas significant differences were observed between the mean values obtained from the radial and posterior tibial artery for A2 (P=0.002, power=0.89, = 0.26) and A4 (P=0.0001, power=0.99, =0.47). A significant correlation was observed between radial A5 and posterior tibial A5 (P=0.001). There was no significant difference between sites for A5 (P=0.21, power=0.24,=0.05).

CA (First-Order Model)
The correlation coefficient between sites for CA was not statistically significant (r=-0.006, P=0.97, r2=0.00004; Figure 3A), but a significant difference was observed between the radial and posterior tibial artery (P=0.027, power=0.62, =0.18). The Bland-Altman plot for CA (Figure 3B) quantifies the limits of agreement between measurement sites: 4.9x10-4 to 3.1x10-4 dyne · s · cm5. The 95% confidence intervals for the upper and lower limits of agreement are 7.4x10-4 to -2.5x10-4 dyne · s · cm5 and -0.66x10-4 to -2.5x10-4 dyne · s · cm5, respectively.

C1 and C2 (Third-Order Model)
The correlation coefficients between sites were not statistically significant for either C1 (r=-0.11, P=0.55, r2=0.01; Figure 4A) or C2 (r=0.04, P=0.81, r2=0.002; Figure 5A). There were significant differences in C1 (P=0.04, power=0.54, = 0.12) and C2 (P=0.0001, power=1.0, =0.61) between the radial and posterior tibial artery. The Bland-Altman plots for C1 (Figure 4B) and C2 (Figure 5B) quantify the limits of agreement between measurement sites: 2.44x10-4 to -4.29x10-4 dyne · s · cm5 and 2.19x10-4 to -9.41x10-4 dyne · s · cm5, respectively. For C1, the 95% confidence intervals for the upper and lower limits of agreement are 1.32 to 3.56 dyne · s · cm5 and -5.41 to -3.17 dyne · s · cm5, respectively. For C2, the 95% confidence intervals for the upper and lower limits of agreement are 0.39 to 3.99 dyne · s · cm5 and -7.61 to -11.21 dyne · s · cm5, respectively.


*    Discussion
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
*Discussion
down arrowReferences
 
Precise quantitation of arterial compliance variables is the cornerstone of future identification of individuals in whom premature vascular stiffening signals increased systolic blood pressure and increased cardiovascular risk. Present data, however, strongly suggest that the problems encountered in using Windkessel-derived diastolic pulse contour analysis in humans are similar to those reported in dogs, where the third-order model has been found to yield "unreliable estimates of arterial compliance."12 Our results show that the lumped-parameter Windkessel models yield different results from the upper and lower limb. These differences probably represent the influences of regional circulatory properties and suggest that a simple "systemic measurement" of whole-body, proximal or distal compliance cannot be reliably obtained from peripheral tonography and diastolic pulse contour analysis.

From a theoretical perspective, diastolic pulse contour analysis indirectly estimates arterial compliance by fitting the diastolic portion of an arterial waveform to a lumped-parameter model. This lumped-parameter model of whole-body compliance is valid only if (1) the pressure wave speed is high enough so that all segments of the large and small arteries are pressurized simultaneously, and (2) no reflection sites exist. Under these 2 conditions, peripheral pressure waveforms at different arterial sites differ only in scale, and thus, compliance variables calculated from any site would be equivalent. However, pressure changes do not occur instantaneously throughout the arterial tree and the arterial tree is not a reflectionless system.13 Instead, after each systole, a pressure wave travels downstream with variable intrinsic velocities that depend on local arterial wall properties. Reflected waves emanate from points of significant impedance mismatch, and the summation of antegrade and retrograde waves determines the morphology of the composite arterial waveform at any given point along the arterial tree. Because of differences in the length of individual arteries, the number of regional reflection sites, and the stiffness of the individual arterial walls, the morphology, timing, and magnitude of reflected waves are intrinsically different in the wrist and ankle.14 Thus, Windkessel-derived compliance values in the upper and lower extremities would not be expected to be similar because they represent local, as well as systemic, vascular properties. The validity of these statements is supported by the current data.

The assumption of site-independence has never been fully tested for the basic or modified Windkessel model in man, and existing data are conflicting in animals. In dogs, both similar6,7 and different12 compliance values have been reported when aortic and femoral measurement sites were compared. We chose peripheral sites from the upper and lower limbs where the different morphology of the pressure pulses14 is due to different regional patterns of wave reflection. In the pulse wave morphology of Figure 2A, the second peak is probably a reflected wave, which violates the assumption of the first-order model (ie, that the diastolic pressure decay is monoexponential [Eq. 1]) and alters the Windkessel calculation. In the case of the third-order model, the presence of a reflected wave exerts an even stronger influence on the decaying sinusoid calculation (B in Eq. 3) than on the overall sinusoid decay (A in Eq. 3).

The reliability of obtaining Windkessel-derived compliance values is also of significant concern. Our results are probably not due to methodological artifacts. Both the radial and posterior tibial measurement sites are well situated for tonometry,9 with each artery properly supported between a bony structure and the tonometer. Even though we were able to obtain high-fidelity arterial waveforms with no apparent artifact, some data could not be fit to the Windkessel equations in many subjects without yielding uninterpretable results, such as negative or "zero" coefficients and compliance values (Table 2). Retrospective analysis of tracings in individuals in whom negative compliance values were obtained demonstrated the presence of late-diastolic wave peaks of uncertain origin. These large peaks strongly influence the calculation, converting the sinusoid from a decay pattern (positive compliance value) to an amplification pattern (a negative compliance value).

The model fit was excellent for the data reported. For the first-order model, the coefficient of determination (r2) averaged 0.99±0.04 and 0.99±0.003 for the radial and posterior tibial artery waveforms, respectively. For the third-order model, r2 averaged 0.94±0.03 and 0.96±0.02 for the radial and posterior tibial artery waveforms, respectively. The diastolic waveform variability averaged less than 5% at each measurement site, and the curve-fitting constants derived from the first- and third-order lumped-parameter models had low curve-fitting errors (Table 1).

The poor reliability is also not due to the slight methodological differences between our system and the commercially available HDI/Pulsewave CR-2000 (Hypertension Diagnostics, Inc) system. We have previously reported excellent concordance between the two modified Windkessel-based techniques in individuals in whom interpretable compliance values could be obtained.4

The significant intersite differences observed in this study cannot be attributed to excessive variability in either the radial or posterior tibial diastolic waveforms and probably represent true differences in the respective arterial walls. The first-order model time constant ({tau}) and third-order model curve fitting constants (A2 and A4) were significantly different between the radial and posterior tibial artery. Because the constants were not correlated, the difference between sites was not systematic. The time constant ({tau}), the curve-fitting constants (A2 and A4), and their derived compliance values (CA, C1, and C2) were not only uncorrelated between sites, but significantly different as well. The third-order model curve-fitting constant A5, which describes the frequency of oscillation, was correlated between sites, suggesting that the lack of correlation in other compliance variables could be due to the time delay between the incident and reflected wave. The A5 correlation further suggests that the same reflection sites are found in both the upper and lower extremity.

Our results do not rule out the possibility that the compliance variables (CA, C1, and C2) can serve as biomarkers of arterial dysfunction or disease. Abnormal changes in C2 have been reported to be altered by aging, hypertension, and congestive heart failure.15 However, the physiological meaning of Windkessel-derived compliance values remains unclear.


*    Acknowledgments
 
This work was supported by Pilot Clinical Pharmacology Training Grant no. FDT000889.


*    Footnotes
 
This work was presented in part at the 15th Scientific Meeting of the American Society of Hypertension, New York, NY, May 16–20, 2000.

Received January 10, 2002; accepted March 15, 2002.


*    References
up arrowTop
up arrowAbstract
up arrowIntroduction
up arrowMethods
up arrowResults
up arrowDiscussion
*References
 

  1. O’Rourke MF, Yaginuma T. Wave reflections and the arterial pulse. Arch Intern Med. 1984; 144: 366–371.[Abstract]
  2. Benetos A, Safar M, Rudnichi A, Smulyan H, Richard JL, Ducimetiere P, Guize L. Pulse pressure: a predictor of long-term cardiovascular mortality in a French male population. Hypertension. 1997; 30: 1410–1415.[Abstract/Free Full Text]
  3. Mitchell GF, Pfeffer MA. Pulsatile hemodynamics in hypertension. Curr Opin Cardiol. 1999; 14: 361–369.[CrossRef][Medline] [Order article via Infotrieve]
  4. Izzo JL Jr, Manning TS, Shykoff BE. Office blood pressures, arterial compliance and estimated cardiac load. Hypertension. 2001; 38: 1467–1470.[Abstract/Free Full Text]
  5. Goldwyn RM, Watt T. Arterial pressure pulse contour analysis via a mathematical model for the clinical quantification of human vascular properties. IEEE Trans Biomed Eng. 1967; 14: 11–17.
  6. Watt T, Burrus C. Arterial pressure contour analysis for estimating human vascular properties. J Appl Physiol. 1976; 40: 171–176.[Abstract/Free Full Text]
  7. Finkelstein SM, Cohn JN. First- and third-order models for determining arterial compliance. J Hypertens. 1992; 10: S11–S14.[CrossRef]
  8. Yin FCP, Liu Z. Arterial compliance-physiological viewpoint.In: Westerhof N, Gross DR, eds. Vascular Dynamics: Physiological Perspectives. New York, NY: Plenum Press; 1989: 9–22.
  9. Drzewiecki GM, Melbin J, Noordergraaf A. Arterial tonometry: review and analysis. Biomechanics. 1983; 16: 141–152.
  10. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1: 307–310.[CrossRef][Medline] [Order article via Infotrieve]
  11. Stevens J. Applied Multivariate Statistics for the Social Sciences. 2nd ed. Hillsdale, NJ: Lawrence Erlbaum Associates; 1992.
  12. Fogliardi R, Burattini R, Shroff SG, Campbell KB. Fit to diastolic arterial pressure by third-order lumped model yields unreliable estimates of arterial compliance. Med Eng Phys. 1996; 18: 225–233.[CrossRef][Medline] [Order article via Infotrieve]
  13. Nichols WW, O’Rourke MF. McDonald’s Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles. 4th ed. London: Arnold; 1998: 220–222.
  14. Kroeker EJ, Wood EH. Beat-to-beat alterations in relationship of simultaneously recorded central and peripheral arterial pressure pulses during Valsalva maneuver and prolonged expiration in man. J Appl Physiol. 1956; 8: 483–494.[Free Full Text]
  15. Cohn JN, Finkelstein SM. Abnormalities of vascular compliance in hypertension, aging and heart failure. J Hypertens. 1992; 10: S61–S64.



This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
X. Chen, J.-K. Kim, J. A. Sala-Mercado, R. L. Hammond, R. I. Elahi, T. J. Scislo, G. Swamy, D. S. O'Leary, and R. Mukkamala
Estimation of the total peripheral resistance baroreflex impulse response from spontaneous hemodynamic variability
Am J Physiol Heart Circ Physiol, January 1, 2008; 294(1): H293 - H301.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
N. Nair, R. K Oka, L. D Waring, E. M Umoh, C B. Taylor, and J. P Cooke
Vascular compliance versus flow-mediated vasodilation: correlation with cardiovascular risk factors
Vascular Medicine, November 1, 2005; 10(4): 275 - 283.
[Abstract] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
J. J. Oliver and D. J. Webb
Noninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Arterioscler. Thromb. Vasc. Biol., April 1, 2003; 23(4): 554 - 566.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Manning, T. S.
Right arrow Articles by Izzo, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Manning, T. S.
Right arrow Articles by Izzo, J. L., Jr
Related Collections
Right arrow Pulmonary biology and circulation
Right arrow Coronary circulation