Donate Help Contact The AHA Sign In Home
American Heart Association
Hypertension
Search: search_blue_button Advanced Search
Hypertension. 2003;42:e6-
Published online before print August 4, 2003, doi: 10.1161/01.HYP.0000087200.21513.68
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
42/3/e6    most recent
01.HYP.0000087200.21513.68v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hope, S. A.
Right arrow Articles by Chowienczyk, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hope, S. A.
Right arrow Articles by Chowienczyk, P. J.
Related Collections
Right arrow Other hypertension
Right arrow Clinical Studies

(Hypertension. 2003;42:e6.)
© 2003 American Heart Association, Inc.


Letters to the Editor

Is There Any Advantage to Using an Arterial Transfer Function?

Sarah A. Hope; Ian T. Meredith; James D. Cameron

Cardiovascular Research Centre, Monash University, Monash Medical Centre, Victoria, Australia

To the Editor:

We read with interest the paper by Millasseau et al,1 which raises the question of whether the application of an arterial transfer function to noninvasively acquired radial artery pressure waveform data is necessary for the estimation of central aortic waveform characteristics. Although the conclusion that this approach offers no advantage over the simple analysis of untransformed radial artery pressure waveforms is valid, it should be remembered that the approach of these authors demonstrates only comparability and does not add to the debate as to whether arterial transfer function techniques enable accurate estimation of central aortic waveform parameters, because no directly measured central aortic waveforms were available for comparison.

Our own findings, derived from noninvasive radial waveforms compared with directly measured central aortic waveforms, have demonstrated close relationships between several radial and measured central aortic waveform parameters proposed to be of potential clinical value, such as systolic and diastolic pressure time integrals.2,3 However, the radial artery augmentation index (AI) was unrelated to, or at best weakly correlated with, the directly measured central aortic AI.2,3 The poor correlation and wide limits of agreement between directly measured central aortic and transfer function-derived AI observed by most authors is explained by the persisting close correlation between the radial AI and that derived by the application of a generalized transfer function to this data, which has been confirmed by Millasseau et al1,3–6 Those who have reported correlation between measured and derived values have done so using combined data sets including repeated data from each individual before and after an intervention.7,8 Given that such repeated values are correlated within the individual (Sarah A. Hope, Ian T. Meredith, James D. Cameron, unpublished observations), this practice will falsely strengthen any underlying correlation or indeed create an apparent statistical correlation where no such correlation exists in the baseline data. Millasseau and colleagues have demonstrated changes in the radial AI with interventions that are correlated with the AI of the waveform derived by the application of an arterial transfer function to the same data.1 As we have previously noted and as is reiterated in the editorial accompanying this paper, given that the radial artery waveform contains all the data utilized to synthesize the transfer function-derived waveform, this is not surprising.9,10 These findings do not, however, indicate that measured central aortic AI is necessarily changing in the same manner.

Much confusion surrounds the use of arterial transfer function techniques. With the substantial equivalence between radial waveform parameters and transfer function-derived parameters, much of this confusion might be alleviated by the analysis of untransformed radial waveforms. This approach would also have the advantage that it would dispel the myth that what is being analyzed is a true central aortic waveform rather than simply the result of the application of a low-pass filter to a radial pressure waveform.9 We would therefore support the conclusions of Millasseau and colleagues that the simple analysis of untransformed radial pressure waveforms, in preference to transfer function-derived waveforms, should be considered for the potential to add to the conventional approaches for cardiovascular risk stratification and treatment.

References

  1. Millasseau SC, Patel SJ, Redwood SR, Ritter JM, Chowienczyk PJ. Pressure wave reflection assessed from the peripheral pulse: is a transfer function necessary? Hypertension. 2003; 41: 1016–1020.[Abstract/Free Full Text]
  2. Hope SA, Meredith IT, Cameron JD. A comparison of pressure and time characteristics between aortic and radial pressure waveforms. J Am Coll Cardiol. 2002; 39 (suppl A): 243A.
  3. Hope SA, Tay DB, Meredith IT, Cameron JD. Use of arterial transfer functions for the derivation of aortic waveform characteristics. J Hypertens. 2003; 21: 1299–1305.[CrossRef][Medline] [Order article via Infotrieve]
  4. Chen CH, Nevo E, Fetics B, Pak PH, Yin FC, Maughan WL, Kass DA. Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. Circulation. 1997; 95: 1827–1836.[Abstract/Free Full Text]
  5. Fetics B, Nevo E, Chen CH, Kass DA. Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry. IEEE Trans Biomed Eng. 1999; 46: 698–706.[CrossRef][Medline] [Order article via Infotrieve]
  6. Hope SA, Tay DB, Meredith IT, Cameron JD. Application of Fourier domain arterial transfer functions for the estimation of aortic waveform characteristics from radial pressure waveforms. J Am Coll Cardiol. 2002; 39 (suppl B): 338B.
  7. Takazawa K, O’Rourke MF, Fujita M, Tanaka N, Takeda K, Kurosu F, Ibukiyama C. Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function. Z Kardiol. 1996; 85: 137–139.
  8. Segers P, Qasem A, De Backer T, Carlier S, Verdonck P, Avolio A. Peripheral "oscillatory" compliance is associated with aortic augmentation index. Hypertension. 2001; 37: 1434–1439.[Abstract/Free Full Text]
  9. Cameron JD. Assessment of drug-class effects on central aortic blood pressure. Clin Sci (Lond). 2002; 103: 501–502.[Medline] [Order article via Infotrieve]
  10. McVeigh GE. Pulse waveform analysis and arterial wall properties. Hypertension. 2003; 41: 1010–1011.[Free Full Text]

Response: Aortic Augmentation Index and Radial-to-Aortic Transfer Function

Sandrine C. Millasseau; James M. Ritter; Philip J. Chowienczyk

Clinical Pharmacology Department, St Thomas’ Hospital, King’s College, London, United Kingdom

We thank Hope and colleagues for their comments on our recent study reporting poor agreement between aortic augmentation index (AIx) derived by applying transfer functions (TF) to the carotid and radial pressure waveforms.1–2 They correctly emphasize that our study was comparative and did not identify whether inaccuracies in the radial-to-aortic TF or in the carotid-to-aortic TF or both were responsible for the variation in aortic AIx obtained from the transformed carotid and radial waveforms. We did, however, suggest that the majority of the error was likely to result from the radial-to-aortic TF because of the similarity between carotid and aortic waveforms. In a study that was in press at the time our paper was published, Hope and colleagues have now compared values of aortic AIx derived using a radial-to-aortic TF with direct invasive measurements.3 They find little, if any, relationship between measured values of aortic AIx and values estimated from the radial artery using a TF, confirming the poor performance of a radial-to-aortic TF in estimating aortic AIx. Their study was performed in older subjects (mean age 63±10 years) undergoing cardiac catheterization. It is unlikely that better results would have been obtained in younger subjects because, in our comparative study, we found no correlation between aortic AIx obtained from transformed carotid and radial waveforms in young healthy subjects. The new data provided by Hope and colleagues provides convincing evidence that a radial-to-aortic TF does not provide an accurate measurement of aortic AIx. The purpose of a TF is to aid with the interpretation of a measurement; it cannot add any information. The radial-to-aortic TF improves the evaluation of systolic blood pressure by providing an estimation of central systolic blood pressure. By contrast, in the case of aortic AIx, the TF offers little advantage: the transformed radial pulse may provide useful information about pressure wave reflection (as does the untransformed pulse) but does not tell us about true aortic AIx. We are in complete agreement with Hope and colleagues that simple analysis of the untransformed radial pulse may lead to less confusion when assessing wave reflection.

References

  1. Millasseau SC, Patel SJ, Redwood SR, Ritter JM, Chowienczyk PJ. Pressure wave reflection assessed from the peripheral pulse: is a transfer function necessary? Hypertension. 2003; 41: 1016–1020.[Abstract/Free Full Text]
  2. McVeigh GE. Pulse waveform analysis and arterial wall properties. Hypertension. 2003; 41: 1010–1011.[Free Full Text]
  3. Hope SA, Tay DB, Meredith IT, Cameron JD. Use of arterial transfer functions for the derivation of aortic waveform characteristics. J Hypertens. 2003; 21: 1299–1305.[CrossRef][Medline] [Order article via Infotrieve]



This article has been cited by other articles:


Home page
CirculationHome page
S. Oparil and J. L. Izzo Jr
Pulsology Rediscovered: Commentary on the Conduit Artery Function Evaluation (CAFE) Study
Circulation, March 7, 2006; 113(9): 1162 - 1163.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
42/3/e6    most recent
01.HYP.0000087200.21513.68v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hope, S. A.
Right arrow Articles by Chowienczyk, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hope, S. A.
Right arrow Articles by Chowienczyk, P. J.
Related Collections
Right arrow Other hypertension
Right arrow Clinical Studies