(Hypertension. 2006;47:1203.)
© 2006 American Heart Association, Inc.
Original Articles |
From the Department of Medicine (J.E.S., M.I.B., T.H.M.), School of Human Movement Studies (J.E.S., J.S.C.), and Department of Cardiology (R.L., J.F., P.G.), University of Queensland, Princess Alexandra Hospital, Queensland, Australia; Department of Engineering (A.M.Q.), University of New South Wales, Sydney, Australia; and Clinical Pharmacology Unit (I.B.W.), University of Cambridge, Addenbrookes Hospital, Cambridge, United Kingdom.
Correspondence to James E. Sharman, Department of Medicine, The University of Queensland, Princess Alexandra Hospital, Ipswich Rd Woolloongabba, Brisbane, 4102, Australia. E-mail jsharman{at}soms.uq.edu.au
| Abstract |
|---|
|
|
|---|
Key Words: exercise blood pressure arteries blood pressure monitoring hypertension, arterial
| Introduction |
|---|
|
|
|---|
Despite the accumulation of this evidence using peripheral pressure, there are important limitations of brachial cuff sphygmomanometry. In particular, central and brachial SBP may differ widely between individuals (eg, <5 to >20 mm Hg) because of differences in demographic (eg, age, height, and gender) and hemodynamic (eg, arterial stiffness and pattern of left ventricular ejection) factors affecting wave reflection through the arterial tree.8 During exercise, heart rate increases significantly, and the central to peripheral SBP disparity is exacerbated such that pressure differences may exceed 80 mm Hg.9 In addition, recent work has demonstrated important discordance between peripheral and central BP, especially in relation to treatment response.10 Therefore, a noninvasive method to determine central BP during exercise may provide additional information.
The central arterial pressure waveform can be derived noninvasively from the radial pulse using applanation tonometry and application of a generalized transfer function, which corrects for pressure wave amplification in the upper limb.8 Such a device is commercially available, and derived central waveforms have been validated in various hemodynamic settings1113 but not in the context of aerobic exercise. Because determination of exercise central BP may be of clinical value, we sought to test the validity of its noninvasive measurement using a standard clinical device.
| Methods |
|---|
|
|
|---|
|
Study Protocol
The study involved acquisition and comparison of resting and exercise pressure waveforms recorded from the ascending aorta: (1) directly by catheter (position fluoroscopically confirmed); (2) derived from radial applanation tonometry and pulse wave analysis; and (3) the radial artery directly by applanation tonometry. After the angiographic procedure, all of the pressure waveforms were simultaneously recorded at rest and during 1-legged (femoral approach) or 2-legged (brachial approach) supine cycling using a portable cycle ergometer (model 881E, Monark). Patients cycled for 3 to 6 minutes at 50 to 80 rpm and at a light to moderate intensity. Resistance on the ergometer was adjusted in order for each patient to maintain a steady-state heart rate. A specific exercise intensity based on percentage of estimated maximal heart rate was not defined for each individual, because most patients (83%) were medicated with ß- adrenergic receptor blockers, thus blunting the normal exercise heart rate response.
Pressure Waveform Acquisition
A Millar model SSD-1008, 6F micromanometer-tipped luminal catheter (Millar Instruments) with a 0.025-in guide wire was used for all of the procedures. For each study, catheter pressure signals were calibrated to 0 and 100 mm Hg using a Millar transducer control unit (models TC-510 or TCB-500, Millar Instruments). Radial pressure waveforms were acquired by servocontrolled applanation tonometry (Colin CBM-7000, Colin Corp). Pulse wave analysis was used to synthesize an ascending aortic pressure waveform from the radial pulse using customized software (SphygmoCor 7.01, AtCor Medical) with a previously validated generalized transfer function.1113 All of the waveforms were digitized at 200 Hz (ML785 PowerLab/8SP, ADInstruments) and saved using Chart 5 for Windows software (ADInstruments) for offline analysis. For each of the 3 waveforms, a simultaneous 12-s period at rest and during exercise was ensemble averaged and analyzed at 128 Hz using the SphygmoCor 7.01 software.
The radial pressure waveform was calibrated using the catheter mean arterial pressure (MAP) and diastolic BP (DBP). The MAP was derived by integration of the central pressure waveform from the ensemble averaged data. Pulse pressure (PP) was calculated as SBPDBP. On the central pressure waveform, the subendocardial viability ratio was calculated by the ratio of diastolic to systolic pressuretime integral, which is a measure of subendocardial perfusion capacity.14 Because differences between central and peripheral BP may have clinical significance,15 we also assessed PP amplification by the ratio of radial:catheter central PP.
Generalized Transfer Function
Using Fourier frequency analysis, each pressure wave consists of series of harmonic (sine) waves at multiples of heart rate frequency. The transfer function, which converts radial to aortic pressure waveform, is the ratio in amplitude and phase of radial and aortic pressure harmonics. The generalized transfer function of the pressure pulse between sites A (eg, aorta) and B (eg, radial artery) is defined by Karamanoglu et al11 as follows: equation
|
|
where PA(
) and PB(
) represent the frequency domain of the pressure wave at sites A and B, respectively [ie, PA(
)=MA(
)ej
and PB(
)=MB(
) ej
, where site A is the ascending aorta and site B is the radial artery,
is the angular frequency, MA(
) and MB(
) and
A(
) and
B(
) are the moduli and phases of respective pressure waves].
Statistics
Data were analyzed using SPSS software version 11.0 (SPSS Inc). Pearson productmoment correlation coefficient (r) was used to determine associations between variables. BlandAltman plots were used to assess agreement between methods. Dependent t tests were used to compare means. Data were expressed as mean±SD, and P<0.05 was considered significant.
| Results |
|---|
|
|
|---|
|
Patients exercised at a heart rate that was equal to 48±7% (range, 37% to 71%) of maximal age-predicted heart rate (220age). The rate pressure product (heart ratexradial SBP) was increased from resting values by 69% (9924±2965 to 14325±3873; P<0.001). After the angiogram procedure and before the start of exercise, 18 patients were hypertensive (radial BP >140/90 mm Hg), and 10 patients had a hypertensive response to exercise (radial BP
220/105 mm Hg for men and 195/105 mm Hg for women).
Comparison of Invasive and Noninvasive Central Pressure Measurements
As shown in Table 2, at rest and during exercise there was high correlation and excellent agreement between directly recorded and transfer functionderived aortic SBP, DBP, end systolic pressure, subendocardial viability ratio, and ejection duration. During exercise, the mean difference between direct and derived measures of central PP was marginally higher because of the combination of slight overestimation for DBP and underestimation of SBP. However, the correlation between methods for central PP remained high. Subgroup analysis of resting and exercise central SBP in patients receiving ß-blocker (n=25) or angiotensin-converting enzyme inhibitor (n=14) medication showed similar mean results (ie, <1 mm Hg) to the total population.
Figure 1 depicts the relationship between catheter and transfer functionderived central SBP for resting and exercise conditions. These data are also represented by BlandAltman plot in Figure 2. Example recordings of the direct and transfer functionderived pressure waveforms in a female patient at rest and during exercise are depicted in Figure 3. For this waveform series, the average catheter and derived SBP was 151±4 and 147±5 mm Hg, respectively, at rest (mean difference, 5±2 mm Hg) and 197±4 and 196±6 mm Hg, respectively, during exercise (mean difference, 1±4 mm Hg).
|
|
|
Correlation of Central and Peripheral Pressure Measurements
There was discordance between central and peripheral BP measures at rest and during exercise. At baseline, radial SBP was significantly higher than catheter central SBP (155±33 versus 138±32 mm Hg), and radial PP was significantly higher than catheter central PP (78±18 versus 61±18 mm Hg; for both, P<0.001 and mean difference, 16.3±9.4 mm Hg). Similarly, during exercise, radial SBP and PP were significantly higher than catheter central SBP (180±34 versus 164±33 mm Hg; P<0.001) and central PP (89±21 versus 74±18 mm Hg; P<0.001; for both, P<0.001 and mean difference, 15.5±10.4 mm Hg), respectively.
Although central and radial PP increased during exercise, there was a significantly greater percentage increase in central compared with radial PP (23±21% versus 17±20%; P<0.01). This was contributed to by central SBP increasing significantly more than radial SBP (20±12% versus 17±12%; P<0.05). Overall, there was a significant decrease in the PP amplification ratio from rest (1.30±0.2) to exercise (1.22±0.15; P<0.01). However, there was considerable variation in the PP amplification response to exercise, with a drop occurring in 20 patients (mean, 10±8%) and an increase evident in the remaining 10 patients (mean, 4±4%; total range, 29% to 11%).
| Discussion |
|---|
|
|
|---|
Consistency of Transfer Function Under Different Hemodynamic Conditions
A number of previous studies have tested the effectiveness of a generalized transfer function to estimate central BP after hemodynamic alterations induced by vasoactive drugs or maneuvers including Valsalva, abdominal compression, and temporary occlusion of the inferior vena cava.1113 Using a fluid-filled manometer system of known frequency response, Pauca et al12 found excellent agreement between invasive and transfer functionderived central pressures at rest, which were results similar to our own and those of others.13 Karamanoglu et al11 conducted a retrospective analysis of pressure waveforms in which the amplitude of transfer function between the ascending aorta and the radial artery was compared between different published data, including those in which aortic and radial intra-arterial pressure waves were recorded in humans during exercise.9,16 Despite the exercise-induced cardiovascular changes, the same amplification to that of rest or other hemodynamic transients was reported to
6 Hz, with scatter >4 Hz. Considering that most of the power (ie, &96%) of the ascending aortic pressure pulse is contained in the first 4 harmonics between 0.8 and 4.0 Hz,8 these data strongly suggested that the transfer function in the upper limb was not appreciably altered during exercise, implying that central BP could be reliably estimated. Our results, which are the first to validate the derivation of central pressure waveforms from tonometry during exercise, are consistent with these reported findings.
Effects of Exercise on Central and Peripheral BP
Aerobic exercise elicits a constellation of hemodynamic changes, including increased MAP and cardiac output (because of positive chronotropic and inotropic effects), in addition to idiosyncratic changes in the vascular tone of different vessel beds (eg, upper versus lower limbs).17 The PP between the ascending aorta and the brachial/radial artery is also greatly amplified because of a higher relative increase in peripheral compared with central SBP. Indeed, the SBP difference may be >80 mm Hg during maximal aerobic activity.9 However, the relationship between central and peripheral SBP (ie, the degree of amplification) is subject to considerable individual variation and depends on several factors, including the vasodilatory state of upper limb muscular arteries, as well as the intensity and duration of exercise.9 Therefore, whereas the use of traditional cuff sphygmomanometry during exercise has been shown to provide useful prognostic information, it may give a poor approximation of central systolic loading between individuals. Our results emphasize the potential complimentary role of radial tonometry to acquire closer estimates of true afterload.
Study Limitations
Because our aim was to test the validity of the generalized transfer function, we calibrated the radial waveform by invasive recordings of central MAP and DBP rather than brachial auscultatory measures. This recommended methodology,18 which has been used by others,13 removes the confounding influence of the less accurate brachial cuff recordings. On the other hand, this approach does not reflect how central pressure would be estimated during exercise. Also, we did not screen patients for the presence of upper extremity obstructive atherosclerosis and cannot rule this out as a possible confounding variable.
During exercise, central DBP was slightly overestimated by the transfer function. A previous invasive intra-arterial study has shown radial DBP to be 7% lower than central DBP during submaximal supine cycling.16 It is, therefore, likely that the exercise radial waveform has been calibrated with a DBP higher than the actual value in the radial artery (beyond the normal 1- to 3-mm Hg difference at rest). This error would have introduced an overestimation of derived central DBP together with an underestimation in the amplitude of the central pressure wave during exercise. Indeed, compared with the catheter, such an effect was observed. Importantly, derived values were still within limits of accepted standards for central SBP and DBP (±5 mm Hg or less and SD 8 mm Hg or less).19 This limitation could be resolved by calibrating the radial waveform with invasive radial recordings, although this was not clinically indicated in our study population and would have exposed participants to unacceptable additional risk.
Perspectives
The lack of concordance between central and brachial SBP and PP is well established, with many studies showing the clinical and prognostic importance of the central pressure waveform (derived by radial or carotid tonometry) beyond BP measured at the upper arm.2024 In some studies, an excessively high brachial SBP response to exercise seems to hold more predictive value for cardiovascular morbidity and mortality than resting brachial BP.47 An elevated brachial BP with exercise may be a consequence of excessive upper limb pressure amplification or increased central BP, with the latter being of more pathophysiological importance. The potential clinical significance of the pressure disparities between the heart and upper arm during exercise was raised >35 years ago9 but has never been followed up with larger-scale studies of exercise central BP. Taken together, these findings draw attention to the need to assess the predictive value of central compared with peripheral BP changes during exercise. The results of this current study confirm the efficacy of radial tonometry and pulse wave analysis as a clinical tool for this purpose.
| Acknowledgments |
|---|
| Footnotes |
|---|
Received March 6, 2006; first decision March 25, 2006; accepted April 10, 2006.
| References |
|---|
|
|
|---|
2. Manolio TA, Burke GL, Savage PJ, Sidney S, Gardin JM, Oberman A. Exercise blood pressure response and 5-year risk of elevated blood pressure in a cohort of young adults: the CARDIA study. Am J Hypertens. 1994; 7: 234241.[Medline] [Order article via Infotrieve]
3. Tanji JL, Champlin JJ, Wong GY, Lew EY, Brown TC, Amsterdam EA. Blood pressure recovery curves after submaximal exercise. A predictor of hypertension at ten-year follow-up. Am J Hypertens. 1989; 2: 135138.[Medline] [Order article via Infotrieve]
4. Kurl S, Laukkanen JA, Rauramaa R, Lakka TA, Sivenius J, Salonen JT. Systolic blood pressure response to exercise stress test and risk of stroke. Stroke. 2001; 32: 20362041.
5. Filipovsky J, Ducimetiere P, Safar ME. Prognostic significance of exercise blood pressure and heart rate in middle-aged men. Hypertension. 1992; 20: 333339.
6. Mundal R, Kjeldsen SE, Sandvik L, Erikssen G, Thaulow E, Erikssen J. Exercise blood pressure predicts cardiovascular mortality in middle-aged men. Hypertension. 1994; 24: 5662.
7. Mundal R, Kjeldsen SE, Sandvik L, Erikssen G, Thaulow E, Erikssen J. Exercise blood pressure predicts mortality from myocardial infarction. Hypertension. 1996; 27: 324329.
8. Nichols WW, ORourke MF. McDonalds Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles. London, United Kingdom: Edward Arnold; 1998.
9. Rowell LB, Brengelmann GL, Blackmon JR, Bruce RA, Murray JA. Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man. Circulation. 1968; 37: 954964.
10. The CAFE Investigators, for the Anglo-Scandinavian Cardiac Outcomes Trial (ASCOT) Investigators, CAFE Steering Committee and Writing Committee, Williams B, Lacy PS, Thom SM, Cruickshank K, Stanton A, Collier D, Hughes AD, Thurston H, ORourke M. Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the Conduit Artery Function Evaluation (CAFE) Study. Circulation. 2006; 113: 12131225.
11. Karamanoglu M, ORourke MF, Avolio AP, Kelly RP. An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur Heart J. 1993; 14: 160167.
12. Pauca AL, ORourke MF, Kon ND. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension. 2001; 38: 932937.
13. Chen CH, Nevo E, Fetics B, Pak PH, Yin FC, Maughan WL, Kass DA. Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. Circulation. 1997; 95: 18271836.
14. Buckberg GD, Fixler DE, Archie JP, Hoffman JI. Experimental subendocardial ischemia in dogs with normal coronary arteries. Circ Res. 1972; 30: 6781.
15. Wilkinson IB, Franklin SS, Hall IR, Tyrrell S, Cockcroft JR. Pressure amplification explains why pulse pressure is unrelated to risk in young subjects. Hypertension. 2001; 38: 14611466.
16. Kroeker EJ, Wood EH. Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man. Circ Res. 1955; 3: 623632.
17. Naka KK, Tweddel AC, Parthimos D, Henderson A, Goodfellow J, Frenneaux MP. Arterial distensibility: acute changes following dynamic exercise in normal subjects. Am J Physiol Heart Circ Physiol. 2003; 284: H970H978.
18. Karamanoglu M, Gallagher DE, Avolio AP, ORourke MF. Pressure wave propagation in a multibranched model of the human upper limb. Am J Physiol. 1995; 269: H1363H1369.[Medline] [Order article via Infotrieve]
19. White W, Berson A, Robbins C, Jamieson M, Prisant L, Roccella E, Sheps S. National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers. Hypertension. 1993; 21: 504509.
20. Weber T, Auer J, ORourke MF, Kvas E, Lassnig E, Berent R, Eber B. Arterial stiffness, wave reflections, and the risk of coronary artery disease. Circulation. 2004; 109: 184189.
21. Safar ME, Blacher J, Pannier B, Guerin AP, Marchais SJ, Guyonvarch PM, London GM. Central pulse pressure and mortality in end-stage renal disease. Hypertension. 2002; 39: 735738.
22. London GM, Blacher J, Pannier B, Guerin AP, Marchais SJ, Safar ME. Arterial wave reflections and survival in end-stage renal failure. Hypertension. 2001; 38: 434438.
23. Boutouyrie P, Bussy C, Lacolley P, Girerd X, Laloux B, Laurent S. Association between local pulse pressure, mean blood pressure, and large-artery remodelling. Circulation. 1999; 100: 13871393.
24. Marchais SJ, Guerin AP, Pannier BM, Levy BI, Safar ME, London GM. Wave reflections and cardiac hypertrophy in chronic uremia. Influence of body size. Hypertension. 1993; 22: 876883.
This article has been cited by other articles:
![]() |
D. J. Holland, J. E. Sharman, R. L. Leano, and T. H. Marwick Gender differences in systolic tissue velocity: role of left ventricular length Eur J Echocardiogr, December 1, 2009; 10(8): 941 - 946. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Sharman, J. E. Davies, C. Jenkins, and T. H. Marwick Augmentation Index, Left Ventricular Contractility, and Wave Reflection Hypertension, November 1, 2009; 54(5): 1099 - 1105. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Sharman, J. Brown, D. J. Holland, G. Macdonald, K. Kostner, and T. H. Marwick Influence of Altered Blood Rheology on Ventricular-Vascular Response to Exercise Hypertension, November 1, 2009; 54(5): 1092 - 1098. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. P. Avolio, L. M. Van Bortel, P. Boutouyrie, J. R. Cockcroft, C. M. McEniery, A. D. Protogerou, M. J. Roman, M. E. Safar, P. Segers, and H. Smulyan Role of Pulse Pressure Amplification in Arterial Hypertension: Experts' Opinion and Review of the Data Hypertension, August 1, 2009; 54(2): 375 - 383. [Full Text] [PDF] |
||||
![]() |
E. A. Dawson, M. A. Black, J. Pybis, N. T. Cable, and D. J. Green The impact of exercise on derived measures of central pressure and augmentation index obtained from the SphygmoCor device J Appl Physiol, June 1, 2009; 106(6): 1896 - 1901. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. McEniery, B. J. McDonnell, A. So, S. Aitken, C. E. Bolton, M. Munnery, S. S. Hickson, Yasmin, K. M. Maki-Petaja, J. R. Cockcroft, et al. Aortic Calcification Is Associated With Aortic Stiffness and Isolated Systolic Hypertension in Healthy Individuals Hypertension, March 1, 2009; 53(3): 524 - 531. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. E. Westerhof, I. Guelen, W. J. Stok, H. A. J. Lasance, C. A. P. L. Ascoop, K. H. Wesseling, N. Westerhof, W. J. W. Bos, N. Stergiopulos, and J. A. E. Spaan Individualization of transfer function in estimation of central aortic pressure from the peripheral pulse is not required in patients at rest J Appl Physiol, December 1, 2008; 105(6): 1858 - 1863. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. D. Chantler, E. G. Lakatta, and S. S. Najjar Arterial-ventricular coupling: mechanistic insights into cardiovascular performance at rest and during exercise J Appl Physiol, October 1, 2008; 105(4): 1342 - 1351. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. McEniery, Yasmin, B. McDonnell, M. Munnery, S. M. Wallace, C. V. Rowe, J. R. Cockcroft, I. B. Wilkinson, and on Behalf of the Anglo-Cardiff Collaborative Trial Central Pressure: Variability and Impact of Cardiovascular Risk Factors: The Anglo-Cardiff Collaborative Trial II Hypertension, June 1, 2008; 51(6): 1476 - 1482. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Munir, B. Jiang, A. Guilcher, S. Brett, S. Redwood, M. Marber, and P. Chowienczyk Exercise reduces arterial pressure augmentation through vasodilation of muscular arteries in humans Am J Physiol Heart Circ Physiol, April 1, 2008; 294(4): H1645 - H1650. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Sharman, C. M. McEniery, R. Campbell, P. Pusalkar, I. B. Wilkinson, J. S. Coombes, and J. R. Cockcroft Nitric Oxide Does Not Significantly Contribute to Changes in Pulse Pressure Amplification During Light Aerobic Exercise Hypertension, April 1, 2008; 51(4): 856 - 861. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Shimizu and K. Kario Review: Role of the augmentation index in hypertension Therapeutic Advances in Cardiovascular Disease, February 1, 2008; 2(1): 25 - 35. [Abstract] [PDF] |
||||
![]() |
D. G. Edwards, C. R. Mastin, and R. W. Kenefick Wave reflection and central aortic pressure are increased in response to static and dynamic muscle contraction at comparable workloads J Appl Physiol, February 1, 2008; 104(2): 439 - 445. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Qasem and A. Avolio Determination of Aortic Pulse Wave Velocity From Waveform Decomposition of the Central Aortic Pressure Pulse Hypertension, February 1, 2008; 51(2): 188 - 195. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Agabiti-Rosei, G. Mancia, M. F. O'Rourke, M. J. Roman, M. E. Safar, H. Smulyan, J.-G. Wang, I. B. Wilkinson, B. Williams, and C. Vlachopoulos Central Blood Pressure Measurements and Antihypertensive Therapy: A Consensus Document Hypertension, July 1, 2007; 50(1): 154 - 160. [Full Text] [PDF] |
||||
![]() |
I. J. Kullo and A. R. Malik Arterial Ultrasonography and Tonometry as Adjuncts to Cardiovascular Risk Stratification J. Am. Coll. Cardiol., April 3, 2007; 49(13): 1413 - 1426. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Hypertension Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2006 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |