(Hypertension. 1995;26:912-918.)
© 1995 American Heart Association, Inc.
Articles |
From The Fourth International Consensus Conference on 24-Hour Ambulatory Blood Pressure Monitoring. A complete list of the participants appears at the end of this article.
Correspondence to Jan A. Staessen, MD, PhD, Klinisch Laboratorium Hypertensie, Inwendige Geneeskunde-Cardiologie, U.Z. Gasthuisberg, Herestraat 49, B-3000 Leuven, Belgium.
Abstract This review, based on the Fourth International Consensus Conference on Ambulatory Blood Pressure Monitoring (Leuven, Belgium, 1994), deals with the technical aspects of ambulatory blood pressure monitoring. Ambulatory blood pressure monitoring by noninvasive intermittent techniques is widely used despite artifacts due to cuff size, movement, body position, short-term blood pressure variability, and interference with sleep. The performance of the currently available monitors under truly ambulatory conditions and during exercise remains a matter of debate, as are the procedures required to validate portable monitors under these circumstances. There is general agreement that whenever a monitor is to be used in special populations, such as older subjects or pregnant women, or in special conditions, such as exercise, a specific demonstration of its accuracy in these defined subgroups or conditions is warranted. Whether the auscultatory or oscillometric method is preferred remains controversial because each technique has specific advantages and disadvantages and because both can provide accurate results. Most experts in the field strongly believe that manufacturers should disclose the algorithms of their devices and that they should specify all changes made to the hardware and software of a previously validated monitor. Finally, the development of the volume-clamp method, which makes continuous noninvasive registration of blood pressure at the finger possible in both stationary and ambulatory conditions, opens new perspectives in research, in particular in relation to short-term blood pressure variability.
Key Words: blood pressure monitoring, ambulatory blood pressure determination blood pressure monitors
This article has been cited by other articles:
![]() |
J. L. Newton, A. Sheth, J. Shin, J. Pairman, K. Wilton, J. A. Burt, and D. E. J. Jones Lower Ambulatory Blood Pressure in Chronic Fatigue Syndrome Psychosom Med, April 1, 2009; 71(3): 361 - 365. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Jones, G. Atkinson, A. Leary, K. George, M. Murphy, and J. Waterhouse Reactivity of Ambulatory Blood Pressure to Physical Activity Varies With Time of Day Hypertension, April 1, 2006; 47(4): 778 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Li, J.-G. Wang, E. Dolan, P.-J. Gao, H.-F. Guo, T. Nawrot, A. V. Stanton, D.-L. Zhu, E. O'Brien, and J. A. Staessen Ambulatory Arterial Stiffness Index Derived From 24-Hour Ambulatory Blood Pressure Monitoring Hypertension, March 1, 2006; 47(3): 359 - 364. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. de Paula Santos, A. L. F. Braga, D. M. A. Giorgi, L. A. A. Pereira, C. J. Grupi, C. A. Lin, M. A. Bussacos, D. M. T. Zanetta, P. H. do Nascimento Saldiva, and M. T. Filho Effects of air pollution on blood pressure and heart rate variability: a panel study of vehicular traffic controllers in the city of Sao Paulo, Brazil Eur. Heart J., January 2, 2005; 26(2): 193 - 200. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A Staessen, E. T O'Brien, L. Thijs, and R. H Fagard Modern approaches to blood pressure measurement Occup. Environ. Med., August 1, 2000; 57(8): 510 - 520. [Abstract] [Full Text] |
||||
![]() |
J. A. Staessen Blood Pressure-Measuring Devices : Time to Open Pandora's Box and Regulate Hypertension, May 1, 2000; 35(5): 1037 - 1037. [Full Text] [PDF] |
||||
![]() |
P Owens and E O'Brien Hypotension in patients with coronary disease: can profound hypotensive events cause myocardial ischaemic events? Heart, October 1, 1999; 82(4): 477 - 481. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Thijs, J. A. Staessen, H. Celis, R. de Gaudemaris, Y. Imai, S. Julius, and R. Fagard Reference Values for Self-recorded Blood Pressure: A Meta-analysis of Summary Data Arch Intern Med, March 9, 1998; 158(5): 481 - 488. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Redon, C. Campos, M. L. Narciso, J. L. Rodicio, J. M. Pascual, and L. M. Ruilope Prognostic Value of Ambulatory Blood Pressure Monitoring in Refractory Hypertension : A Prospective Study Hypertension, February 1, 1998; 31(2): 712 - 718. [Abstract] [Full Text] [PDF] |
||||
|
Hypertension Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1995 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |